Copper Fitting Soldering Preparation
110 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

How do you prepare a copper fitting for soldering?

  • Heat the fitting without cleaning it.
  • Use a lubricant on the fitting.
  • Clean the inside of the fitting. (correct)
  • None of the above.

Grinder work in a plant is related to:

  • Grinding metal surfaces (correct)
  • Welding components
  • Cutting fabric
  • Polishing wood

What is required for the schedule of pipe when joining a threaded coupling to 2 pieces of 4” pipe?

  • Schedule 40 (correct)
  • Schedule 10
  • Schedule 80
  • Schedule 20

How do you cut pipe in a trench with limited space?

<p>4-wheel cutters (A)</p> Signup and view all the answers

What is the field performance of a fire pump?

<p>150% capacity at 65% head (B)</p> Signup and view all the answers

How often is a hydrostatic test required for an ABC extinguisher?

<p>Every 12 years (B)</p> Signup and view all the answers

What is the shape of a Class B fire extinguisher?

<p>Square (B)</p> Signup and view all the answers

What power tool is used for installing post-installed anchors?

<p>Hammer drill (A)</p> Signup and view all the answers

If the air compressor is cycling on and off, what should you do?

<p>Drain the compressor tank through the lowest cock (A)</p> Signup and view all the answers

What size pipe enters the cold space for an INSIDE enclosure?

<p>30” (A)</p> Signup and view all the answers

What size is the fire boat connection?

<p>6 inches (A)</p> Signup and view all the answers

What size is a Class 2 hose valve?

<p>1-1/2 inches (A)</p> Signup and view all the answers

What is the required slope for a branch line in a freezer?

<p>1/2” per 10 feet (A)</p> Signup and view all the answers

What happens if a dry system’s intermediate check valve is defective and you test the system through the alarm test?

<p>It trips (A)</p> Signup and view all the answers

What do you do first when flowing a 2000 GPM fire pump?

<p>Select nozzles (A)</p> Signup and view all the answers

How can you tell when your hard hat expires?

<p>Stamp on hard hat (A)</p> Signup and view all the answers

How many bolts and nuts are required for the installation of a 6” OS&Y valve?

<p>16 3/4&quot; nuts and 16 3/4&quot; bolts (A)</p> Signup and view all the answers

What is the maximum distance between pilot line detectors inside a cooling tower?

<p>8 feet (B)</p> Signup and view all the answers

What is the spacing for pilot line detectors using fixed temperature sensors if they are 6” beside an I-beam that is 12” deep and 8” wide?

<p>Max 8 feet (C)</p> Signup and view all the answers

How often should a sealed control valve be tested?

<p>Weekly (B)</p> Signup and view all the answers

How often should control valves be inspected according to NFPA 13?

<p>Monthly (A)</p> Signup and view all the answers

8-inch pipe flushing

<p>46800 (B)</p> Signup and view all the answers

What is the hydrostatic test requirement for underground pipes?

<p>150 psi ± 5 psi (A)</p> Signup and view all the answers

3-screw ceiling flange with 1/2” lags?

<p>6 inch (B)</p> Signup and view all the answers

What is the maximum distance between 4-way braces?

<p>25 (B)</p> Signup and view all the answers

What is the recommended hang spacing for CPVC pipes?

<p>8 feet 6 inches (B)</p> Signup and view all the answers

How should a pilot tube be used in terms of distance?

<p>1/2&quot; diameter away (A)</p> Signup and view all the answers

If a standpipe only serves a portion of the building, what is required?

<p>Signage stating the portion it serves (A)</p> Signup and view all the answers

What size is the air hose line in a pressure tank?

<p>1/2 inch (A)</p> Signup and view all the answers

How do you clean a pipe for end treatment?

<p>Remove burrs and fins (A)</p> Signup and view all the answers

What do you do to prep grooved pipe for installation?

<p>Grind burrs inside and outside from end of pipe (A)</p> Signup and view all the answers

How often should dry sprinkler systems be tested?

<p>Every 10 years (A)</p> Signup and view all the answers

How often should standard sprinklers be tested?

<p>Every 50 years + 10 years after (A)</p> Signup and view all the answers

What is the minimum pipe size for PVC entering a building?

<p>2 inch (B)</p> Signup and view all the answers

Solder joints in exposed wet pipe systems are

<p>Permitted to be installed in light hazard systems (A)</p> Signup and view all the answers

If multiple drains on floors (1-1/4", 1-1/2", 1-1/4", and 1-1/4") are tied into a common drain, what is the size of the main drain?

<p>2&quot; (A)</p> Signup and view all the answers

Supervision is required for preaction systems when:

<p>more than 20 heads (A)</p> Signup and view all the answers

Where is the QOD (Quick Opening Device) installed?

<p>As close as possible to the valve (A)</p> Signup and view all the answers

A placard on a system riser will identify:

<p>Manufacturer, type of antifreeze solution, and volume of antifreeze used (A)</p> Signup and view all the answers

Antifreeze with a backflow preventer requires:

<p>expansion chamber (A)</p> Signup and view all the answers

Drains draining outside require:

<p>4' of pipe to the exterior wall (A)</p> Signup and view all the answers

If an ordinary head is installed with 6′ of a mounted heater, how do you correct the installation?

<p>Install high-temperature head (B)</p> Signup and view all the answers

What should you do if a sprinkler head is painted?

<p>Remove and replace with listed sprinkler head (A)</p> Signup and view all the answers

What is the maximum distance between residential sprinkler heads?

<p>8 feet (A)</p> Signup and view all the answers

An obstruction is 5'4" away from a side wall. How far above the obstruction can the sidewall be mounted?

<p>2&quot; (A)</p> Signup and view all the answers

What is the coverage area of a CMSA sprinkler head in noncombustible construction?

<p>130 sqft (12’ spacing) (A)</p> Signup and view all the answers

What is required for 25 rack sprinklers fed off an overhead system?

<p>A listed control valve (A)</p> Signup and view all the answers

When replacing uprights with pendents, what is the maximum size nipple you can use?

<p>4&quot; (A)</p> Signup and view all the answers

What is the maximum height for installing post indicator valves?

<p>32-40” (A)</p> Signup and view all the answers

What size auxiliary drain is required on a wet system with a 3-gallon capacity?

<p>1/2 inch (A)</p> Signup and view all the answers

What size auxiliary drain is required for a wet system with a 60-gallon capacity?

<p>1 inch (A)</p> Signup and view all the answers

What is the maximum size of pipe where toggle hangers can be used?

<p>1-1/2” (A)</p> Signup and view all the answers

What is the formula for underground leakage testing of a 660-foot, 6” pipe?

<p>Leakage = 660 * 6” * square root of 200 psi / 148,000 (A)</p> Signup and view all the answers

What is the acceptance test pressure for a water pressure tank with an operating pressure of 175 psi?

<p>225 psi (A)</p> Signup and view all the answers

What kind of wrench do you use to install sprinkler heads?

<p>Adjustable wrench (A), Pipe wrench (C), sprinnkler wrench (D)</p> Signup and view all the answers

What is the rating for a 6500 lb sling?

<p>65,000 lbs (A)</p> Signup and view all the answers

What angle is required for a pipe end when welding?

<p>30 degrees (C)</p> Signup and view all the answers

How often should a 1-1/2” hose valve be tested?

<p>Every 3 years (A)</p> Signup and view all the answers

What is required for scaffolding when working outdoors?

<p>Mud sills (A)</p> Signup and view all the answers

What should you do if you encounter a downed power line in your area?

<p>Secure the area and notify the supervisor (C)</p> Signup and view all the answers

What is the maximum unsupported length for a 1" pipe?

<p>36&quot; (B)</p> Signup and view all the answers

What is the maximum allowable time for an audible alarm to go off in a fire system?

<p>5 minutes (A)</p> Signup and view all the answers

How much time is allowed for an audible alarm to go off for a marine system?

<p>30 seconds (A)</p> Signup and view all the answers

Where is the hydraulic data plate typically located?

<p>On the system riser (A)</p> Signup and view all the answers

When you are late to the site, who should you call first?

<p>The general contractor (GC) or office (C)</p> Signup and view all the answers

What is the coverage area of the maximum sprinkler head?

<p>400 sqft (A)</p> Signup and view all the answers

What size is the discharge pipe for a 2000-gallon fire pump?

<p>10” (A)</p> Signup and view all the answers

How should a drum drip be operated properly?

<p>Shut the upper valve, open the lower valve, then close the lower valve, and finally open the upper valve (A)</p> Signup and view all the answers

What is the best method to join CPVC pipe?

<p>solvent cement (A)</p> Signup and view all the answers

What is the proper method of marking a hole on a pipe?

<p>Use a center punch to mark (A)</p> Signup and view all the answers

Which NFPA standard is used for high foam systems?

<p>NFPA 11 (A)</p> Signup and view all the answers

What must be done prior to installing CO2 pipe?

<p>Clean the inside of the pipe with solvent to remove oil and debris (A)</p> Signup and view all the answers

If a ball drip is leaking, what is the most likely cause?

<p>Service check valve (A)</p> Signup and view all the answers

What is the issue if a dry system will not set?

<p>The clapper is not seated (A)</p> Signup and view all the answers

What is the first step to take if a fire pump is malfunctioning?

<p>Isolate the power (A)</p> Signup and view all the answers

How should acetylene bottles be stored?

<p>Secured upright, with the valve off and regulator off (A)</p> Signup and view all the answers

How are deluge systems typically designed?

<p>By using hydraulic calculations (A)</p> Signup and view all the answers

What is the required strength of a pad for a 5000 lb per square foot load?

<p>5000 lbs (C)</p> Signup and view all the answers

When shall a Fire Department Connection (FDC) be omitted?

<p>In buildings not exceeding 1800 sqft (A)</p> Signup and view all the answers

What is the minimum size drain for a 10" pipe?

<p>2&quot; (B)</p> Signup and view all the answers

What is the required pressure for a hydrostatic test on a system with a working pressure of 175 psi?

<p>225 psi (B)</p> Signup and view all the answers

How often should a preaction system be tested?

<p>annually (A)</p> Signup and view all the answers

What is the maximum spacing for sprinklers in a light hazard occupancy with a ceiling height of less than 12 feet?

<p>12 feet (B)</p> Signup and view all the answers

What should be done if a fire pump loses pressure during operation?

<p>Check the discharge valve for obstruction (A)</p> Signup and view all the answers

What is the required distance from a ceiling-mounted sprinkler to an obstruction in a commercial building?

<p>12 inches (A)</p> Signup and view all the answers

What type of pipe material is used for risers in a wet pipe sprinkler system?

<p>Steel (C)</p> Signup and view all the answers

What is the correct method for testing an antifreeze solution in a sprinkler system?

<p>Perform freeze point test (A)</p> Signup and view all the answers

What is the maximum allowable distance between sprinkler heads in a warehouse with non-combustible construction?

<p>15 feet (B)</p> Signup and view all the answers

Which NFPA standard applies to the installation of fire pumps?

<p>NFPA 20 (A)</p> Signup and view all the answers

What is the minimum required pipe size for a standpipe system in a high-rise building?

<p>4 inch (C)</p> Signup and view all the answers

When should a sprinkler head be replaced?

<p>all the above (D)</p> Signup and view all the answers

What is the primary purpose of a check valve in a sprinkler system?

<p>To prevent backflow (A)</p> Signup and view all the answers

What is the maximum spacing between fire department connections (FDC) on a large building?

<p>100 feet (A)</p> Signup and view all the answers

How long must the standby power source for a fire pump be able to operate during a power outage?

<p>1 hour (A)</p> Signup and view all the answers

Which type of pump is permitted to maintain system pressure?

<p>jockey pump (A)</p> Signup and view all the answers

What is installed on the ground suction tank to prevent air from getting into the fire pump?

<p>vortex plate (A)</p> Signup and view all the answers

What are the key aspects of supervision on a dry pipe system?

<p>Low pressure and control valve temperature (A)</p> Signup and view all the answers

What type of system is a paddle type water alarm installed on?

<p>Wet system (A)</p> Signup and view all the answers

What type of sprinkler requires testing after 10 years?

<p>Dry pendants (A)</p> Signup and view all the answers

When should antifreeze be tested?

<p>Annual (A)</p> Signup and view all the answers

When a sprinkler pipe travels through an unheated room, what is required?

<p>Listed heat tracing that is supervised (A)</p> Signup and view all the answers

What should happen to control valves that are locked?

<p>Inspected monthly (A)</p> Signup and view all the answers

What should be left in the sprinkler head box?

<p>A sprinkler wrench for each head (A)</p> Signup and view all the answers

What is the maximum size for which labeling is not required?

<p>2&quot; (B)</p> Signup and view all the answers

What extinguisher is used to protect against charged equipment?

<p>Class C (C)</p> Signup and view all the answers

What size is the drain when multiple auxiliary drains tie in?

<p>1&quot; (A)</p> Signup and view all the answers

What is the bend radius of a 6" copper fitting with a 40 degree angle of 180 degrees?

<p>7'10-1/4&quot; (A)</p> Signup and view all the answers

What is the first step you should take when starting a job in a confined space?

<p>Hazard assessment (A)</p> Signup and view all the answers

If you are grooving a 4" and then an 8" pipe, what should you do?

<p>Change the wheel (A)</p> Signup and view all the answers

Where does the Fire Department Connection (FDC) tie into on a wet system?

<p>System side, downstream of alarm valve (A)</p> Signup and view all the answers

Flashcards

Copper fitting preparation for soldering

Clean the inside of the fitting.

Grinder work in a plant

Grinding metal surfaces.

Pipe schedule for threaded coupling

Schedule 40 is required when joining a threaded coupling to 2 pieces of 4" pipe.

Pipe cutting in tight trenches

4-wheel cutters are used.

Signup and view all the flashcards

Fire pump field performance

150% capacity at 65% head.

Signup and view all the flashcards

ABC extinguisher test frequency

Every 12 years.

Signup and view all the flashcards

Class B extinguisher shape

Square.

Signup and view all the flashcards

Post-installed anchor tool

Hammer drill is used.

Signup and view all the flashcards

Cycling air compressor issue

Drain the compressor tank through the lowest cock.

Signup and view all the flashcards

Inside enclosure cold space pipe size

30" pipe size.

Signup and view all the flashcards

More Like This

Copper II Sulphate and Alkaline Medium Quiz
0 questions
Copper Smelting Sites Quiz
10 questions
Base Metals and Copper Porphyry Deposits
24 questions
Use Quizgecko on...
Browser
Browser