What is the typical range of square and rectangular radiation fields provided by collimators in teletherapy machines?
What is the typical range of square and rectangular radiation fields provided by collimators in teletherapy machines?
Which type of penumbra is influenced by the transmission through the edge of the collimator block?
Which type of penumbra is influenced by the transmission through the edge of the collimator block?
What can be done to minimize geometric penumbra?
What can be done to minimize geometric penumbra?
What does physical penumbra take into account in addition to transmission and geometric penumbra?
What does physical penumbra take into account in addition to transmission and geometric penumbra?
Signup and view all the answers
Which factor can lead to increased transmission penumbra?
Which factor can lead to increased transmission penumbra?
Signup and view all the answers
What distance should blocks be placed from the patient to avoid excessive electron contamination?
What distance should blocks be placed from the patient to avoid excessive electron contamination?
Signup and view all the answers
How can transmission penumbra be effectively reduced?
How can transmission penumbra be effectively reduced?
Signup and view all the answers
What is the physical penumbra defined as?
What is the physical penumbra defined as?
Signup and view all the answers
What can be a consequence of increasing the source-to-skin distance (SSD)?
What can be a consequence of increasing the source-to-skin distance (SSD)?
Signup and view all the answers
Which of the following statements about penumbra trimmers is true?
Which of the following statements about penumbra trimmers is true?
Signup and view all the answers
What is a common effect of increasing the collimator opening in teletherapy?
What is a common effect of increasing the collimator opening in teletherapy?
Signup and view all the answers
Which type of penumbra is primarily affected by the diameter of the radiation source?
Which type of penumbra is primarily affected by the diameter of the radiation source?
Signup and view all the answers
How can the collimator shape be adjusted to influence penumbra in teletherapy?
How can the collimator shape be adjusted to influence penumbra in teletherapy?
Signup and view all the answers
What determines the location at which the physical penumbra is measured?
What determines the location at which the physical penumbra is measured?
Signup and view all the answers
What is a benefit of using penumbra trimmers in teletherapy?
What is a benefit of using penumbra trimmers in teletherapy?
Signup and view all the answers
Which of the following describes physical penumbra in radiation therapy?
Which of the following describes physical penumbra in radiation therapy?
Signup and view all the answers
When considering transmission penumbra, what is the impact of increasing the source-to-skin distance (SSD)?
When considering transmission penumbra, what is the impact of increasing the source-to-skin distance (SSD)?
Signup and view all the answers
Why should radiation blocks be placed 10 to 20 cm away from the patient?
Why should radiation blocks be placed 10 to 20 cm away from the patient?
Signup and view all the answers
What characteristic of physical penumbra includes aspects of both transmission and geometric penumbra?
What characteristic of physical penumbra includes aspects of both transmission and geometric penumbra?
Signup and view all the answers
Study Notes
Cobalt-60 Teletherapy Machine
- Collimators provide radiation fields of varying sizes, typically from 5×5 to 35×35 cm², at a distance of 80 cm from the radiation source.
- Penumbra refers to the gradient area at the edge of a radiation beam where dose rates change rapidly in relation to distance from the beam axis.
Types of Penumbra
-
Transmission Penumbra: Arises from the inner surface of collimator blocks aligned parallel to the beam's central axis. This type increases with greater source-to-surface distance (SSD) and larger collimator openings. Reducing collimator size can help minimize transmission penumbra.
-
Geometric Penumbra: Caused by the finite diameter of the radiation source. This can be reduced by:
- Utilizing a smaller source diameter.
- Positioning penumbra trimmers as close to the patient's skin as possible (ideal at z = 0).
-
Physical Penumbra: Measured as the distance between specific isodose curves at defined depths (90% and 20% at Dmax). It factors in scattered radiation alongside transmission and geometrical penumbra.
Electron Contamination
- Blocks should be positioned at least 10 to 20 cm away from the patient to minimize excessive electron contamination originating from the blocks.
Cobalt-60 Teletherapy Machine
- Collimators provide radiation fields of varying sizes, typically from 5×5 to 35×35 cm², at a distance of 80 cm from the radiation source.
- Penumbra refers to the gradient area at the edge of a radiation beam where dose rates change rapidly in relation to distance from the beam axis.
Types of Penumbra
-
Transmission Penumbra: Arises from the inner surface of collimator blocks aligned parallel to the beam's central axis. This type increases with greater source-to-surface distance (SSD) and larger collimator openings. Reducing collimator size can help minimize transmission penumbra.
-
Geometric Penumbra: Caused by the finite diameter of the radiation source. This can be reduced by:
- Utilizing a smaller source diameter.
- Positioning penumbra trimmers as close to the patient's skin as possible (ideal at z = 0).
-
Physical Penumbra: Measured as the distance between specific isodose curves at defined depths (90% and 20% at Dmax). It factors in scattered radiation alongside transmission and geometrical penumbra.
Electron Contamination
- Blocks should be positioned at least 10 to 20 cm away from the patient to minimize excessive electron contamination originating from the blocks.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
This quiz covers the essential concepts of Cobalt-60 teletherapy machines, including radiation field sizes and the concept of penumbra. Learn about the different types of penumbra—transmission, geometric, and physical—and how they impact therapy. Perfect for students studying radiation therapy techniques.