Channel Mode Display Quiz
21 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What are the possible settings for the backlight feature?

  • Backlight extinguish after 10 s (correct)
  • Backlight always on (correct)
  • Backlight extinguish after 5 s
  • Backlight always off
  • Which measurement modes are available in the Nuc ID settings?

  • Interval and Continuous
  • Instant and Cyclic
  • Automatic and Manual
  • Automatic and Preset Time (correct)
  • What types of measurements are enabled for the measuring unit gamma?

  • cpm and enhance
  • cpm, cps, rem/h, R/h, Sv/h, and Gy/h (correct)
  • cps and rem/h
  • Sv/h and Gy/r
  • In the sub menu scaler mode background, which option is not included?

    <p>No effect on measurement</p> Signup and view all the answers

    Which measurement units are available for the neutron measuring unit?

    <p>cps and cpm</p> Signup and view all the answers

    What is displayed in the cross-mode display?

    <p>Dose rate and cps value bar graph</p> Signup and view all the answers

    What happens when the 'Info/▲' key is pressed in the scaler mode?

    <p>It starts the measurement</p> Signup and view all the answers

    Which action occurs after the fourth click in channel mode display?

    <p>The gamma channel is displayed again</p> Signup and view all the answers

    How can the cross-mode be activated or deactivated?

    <p>Via PC-Software or settings submenu</p> Signup and view all the answers

    What does the '▼' key control in scaler mode?

    <p>Switch between the gamma, neutron, or dual display</p> Signup and view all the answers

    What is indicated by the Stop symbol blinking during scaler measurements?

    <p>Measurement is currently in progress</p> Signup and view all the answers

    What does pressing the down arrow key display on the first click?

    <p>Neutron channel</p> Signup and view all the answers

    What is the purpose of dose rate calculation during low count rates in cross-mode?

    <p>To allow for longer time calculation</p> Signup and view all the answers

    What happens if no detector pulse is detected within the configured timeout period for the neutron channel?

    <p>Neut.Err. is triggered</p> Signup and view all the answers

    In the context of neutron count rate filtering, what occurs when the filter time is set to 0 seconds?

    <p>The ADF is used</p> Signup and view all the answers

    What must the cycle time be in relation to the measuring time when using the Cyclic & Save option?

    <p>It must exceed the measuring time</p> Signup and view all the answers

    Which parameter controls the duration before an ID measurement begins?

    <p>Waiting time</p> Signup and view all the answers

    What feature allows the RadEye to automatically save spectra after ID measurements?

    <p>Spectrum Autosave</p> Signup and view all the answers

    What occurs when the count rate drops below the specified 'Stop Rate' during an ID measurement?

    <p>The ID measurement is paused</p> Signup and view all the answers

    Which option restricts the instrument's ability to change settings for nuclide ID measurements?

    <p>Maximum measuring time</p> Signup and view all the answers

    In the trigger list, what are the primary actions a user can perform to manage nuclide identification?

    <p>Add and Delete</p> Signup and view all the answers

    Study Notes

    Channel Mode Display

    • First click displays the neutron channel.
    • Second click activates dual channel display.
    • Third click shows graphical count rate gamma.
    • After fourth click, gamma channel reappears.

    Cross-Mode Display

    • Displays dose rate measurement alongside a bar graph of cps values.
    • Count rate alarm thresholds are enabled for quick alert responses.
    • Useful for quickly locating radioactive sources while showing true dose rates.
    • Pressing the Info key shows accumulated dose, mean, and max values.
    • Can be activated/deactivated via PC Software or settings submenu.

    Scaler Mode

    • Select "Scaler" from the operation mode submenu to enter scaler mode.
    • Displays parameters such as number of measurements, mean value, and accumulated counts.
    • The “▼” key toggles between gamma, neutron, or dual display.
    • "Info/▲" key starts the measurement; a countdown may precede measurement if configured.
    • Stop symbol blinks during active measurement.

    Neutron Channel Timeout and Filtering

    • Timeout for the neutron channel can be set; if no pulse is detected, "Neut.Err." is triggered.
    • Filtering options allow for linear ratemeter use based on set time constants.

    Nuclide Identification (Nuclide ID)

    • Maximum measuring time limits auto-measuring time and corresponding auto ID parameters can be modified.
    • Capture type options include automatic measuring time, cyclic & save, and preset time for fixed measurements.
    • Capture settings comprise measuring time, cycle time, and waiting time before ID measurement.
    • Auto ID CR activates ID measurement above the “Start” rate and pauses below the “Stop Rate”.
    • Spectrum autosave functionality is available to automatically store spectra after ID.

    Trigger List and Alarms Management

    • Users can manage the trigger list for nuclide identification, adding or deleting entries.
    • Sub menu options include editing alarms and scaler parameters.
    • Operation modes provide measuring units for both gamma and neutron, including cpm, cps, rem/h, and Sv/h.

    Additional Settings

    • Backlight settings allow continuous illumination or automatic shut-off after 10 seconds.
    • The Scaler Background submenu includes further scaling parameters.
    • NucID settings allow for selection of measurement mode, including automatic and fixed time settings.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    Description

    Test your understanding of the channel mode display functionality in radiation detection equipment. This quiz focuses on the different display options available when operating the DB-103 E RadEye SPRD-GN device. Assess your knowledge of neutron channels, dual channels, and graphical count rate displays.