Burner Management Systems Overview
22 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What does the NFPA 85 Boiler and Combustion Systems Hazard Code define a burner management system (BMS) as?

  • A program allowing full customization of safety parameters for burner operation
  • A system dedicated to combustion safety and operator assistance in starting and stopping fuel preparation and burning equipment (correct)
  • A set of safety protocols for emergency shutdown of combustion equipment
  • A control system ensuring fuel train components are functioning properly

What is the primary purpose of a burner management system (BMS)?

  • To offer customization options for all safety parameters
  • To provide real-time data analytics for operators
  • To ensure burners do not start in unsafe conditions (correct)
  • To maximize fuel efficiency during combustion processes

What type of control system are most burner management systems (BMS) according to the text?

  • Specially designed systems for large industrial burners
  • Open-source software systems accessible to all operators
  • Highly customizable and adaptable to various equipment configurations
  • Programmed combustion controls with limited custom program configuration options (correct)

Which components typically communicate with the burner management system (BMS) to ensure safe burner operation?

<p>Pilot SSOVs, igniters, combustion air switches (C)</p> Signup and view all the answers

According to Factory Mutual (FM), what customization options are typically available to operators using a burner management system (BMS)?

<p>Limited selection of safety parameters like purge, trial for ignition, and flame failure response time (C)</p> Signup and view all the answers

What is the significance of preventing misoperation of fuel preparation and burning equipment as mentioned in the text?

<p>To avoid unsafe conditions during burner operation (B)</p> Signup and view all the answers

What is the purpose of pre-ignition interlock circuitry?

<p>To prevent pre-purge if the SSOV proof-of-closure switches are not shut (A)</p> Signup and view all the answers

How do modern programming controllers differ from older models with electro-mechanical drum sequencers?

<p>Modern controllers prevent alteration of sequences and sequence timing (D)</p> Signup and view all the answers

What is the function of purge proving circuitry in a programming controller?

<p>To initiate and prove a purge in the furnace (B)</p> Signup and view all the answers

Why are pre-ignition interlocks used to ensure the combustion air proving switch is open?

<p>To prevent the burner from going into safety shutdown and lockout (B)</p> Signup and view all the answers

In what way does low-fire position circuitry contribute to burner operation?

<p>By preventing the pilot burner from being blown out by excessive airflow (C)</p> Signup and view all the answers

Why does the text mention that nearly every burner management system Fourth Class Power Engineers operate will be a programming controller?

<p>Because programming controllers have built-in safety features suitable for these systems (B)</p> Signup and view all the answers

What is the purpose of a flame relay in a burner management system?

<p>To amplify the flame signal (D)</p> Signup and view all the answers

Which function is NOT typically provided by primary controls in burner management systems?

<p>Flame detection (C)</p> Signup and view all the answers

What is the maximum allowable main flame establishing period according to CSA B149.3 for burners with interrupted pilots?

<p>10 seconds (A)</p> Signup and view all the answers

Which component is responsible for ensuring no flame is present during the burner off-cycle?

<p>Safe start check (C)</p> Signup and view all the answers

What is the primary reason for a primary control to turn off the pilot safety shut-off valve and igniter?

<p>Excessive ignition times (B)</p> Signup and view all the answers

Which of the following is NOT an interlock that may be wired to the primary control for burner safety?

<p>High temperature sensor (A)</p> Signup and view all the answers

What could be the consequence of the main flame trial-for-ignition period exceeding the prescribed maximum time?

<p>Fuel accumulations leading to explosion (B)</p> Signup and view all the answers

Why is it important for a programming controller to be installed on packaged commercial and industrial boilers with mechanical draft systems?

<p>To provide additional safety features (A)</p> Signup and view all the answers

What aspect of burner management systems does a simple flame relay primarily focus on?

<p>Flame detection and amplification (B)</p> Signup and view all the answers

What is the main function of a primary controller during the timed main Flame Trial-for-Ignition Period?

<p>Maintaining stable main burner flame (C)</p> Signup and view all the answers