What is the maximum additional FSI allowed for Educational Buildings under Chapter 7 of UDCPR?
What is the maximum additional FSI allowed for Educational Buildings under Chapter 7 of UDCPR?
- 4.00
- 3.00 (correct)
- 1.50
- 2.00
What is the premium rate for additional FSI for Charitable Educational Institutions?
What is the premium rate for additional FSI for Charitable Educational Institutions?
- Nil (correct)
- 5%
- 10%
- 15%
Which of the following educational buildings must provide a playground as per the UDCPR?
Which of the following educational buildings must provide a playground as per the UDCPR?
- MBA institute
- Polytechnic
- Pre-primary and nursery school (correct)
- Medical college
If higher FSI is utilized on upper floors of existing educational buildings, is increase in playground area mandatory?
If higher FSI is utilized on upper floors of existing educational buildings, is increase in playground area mandatory?
For vacant land of existing educational buildings, minimum playground area shall be:
For vacant land of existing educational buildings, minimum playground area shall be:
What is the basic and additional FSI allowed for Medical buildings such as hospitals and maternity homes?
What is the basic and additional FSI allowed for Medical buildings such as hospitals and maternity homes?
What is the premium rate for private medical institutions seeking higher FSI?
What is the premium rate for private medical institutions seeking higher FSI?
For Star Category Hotels (2-star and above), what is the maximum premium on additional FSI?
For Star Category Hotels (2-star and above), what is the maximum premium on additional FSI?
Under what condition can Starred Hotels avail the additional FSI?
Under what condition can Starred Hotels avail the additional FSI?
The building potential for starred hotels is considered based on:
The building potential for starred hotels is considered based on:
What % of additional FSI in Mega Tourism Projects may be used for tourism support activities?
What % of additional FSI in Mega Tourism Projects may be used for tourism support activities?
For institutional buildings and banks, the premium rates are as per which previous provisions?
For institutional buildings and banks, the premium rates are as per which previous provisions?
What is the basic FSI permitted for Government and Semi-Government Buildings under Chapter 7?
What is the basic FSI permitted for Government and Semi-Government Buildings under Chapter 7?
What is the maximum building potential allowed for Government buildings on roads ≥18 m width?
What is the maximum building potential allowed for Government buildings on roads ≥18 m width?
What is the premium rate for Semi-Government buildings like Local Authorities?
What is the premium rate for Semi-Government buildings like Local Authorities?
For Public Sector Institutions (e.g., PSU), what is the maximum premium on additional FSI?
For Public Sector Institutions (e.g., PSU), what is the maximum premium on additional FSI?
For MSRTC land, how much FSI out of total can be used for commercial use?
For MSRTC land, how much FSI out of total can be used for commercial use?
What is the minimum percentage of land to be used for principal MSRTC purpose when availing commercial FSI?
What is the minimum percentage of land to be used for principal MSRTC purpose when availing commercial FSI?
What is the required regulatory compliance for maximum height of educational and medical buildings?
What is the required regulatory compliance for maximum height of educational and medical buildings?
In congested areas, who shares the premium collected from higher FSI provisions?
In congested areas, who shares the premium collected from higher FSI provisions?
Flashcards
Max. additional FSI for Educational Buildings?
Max. additional FSI for Educational Buildings?
Maximum additional FSI allowed for Educational Buildings is 3.00.
Premium rate for Charitable Education?
Premium rate for Charitable Education?
Charitable Educational Institutions have a Nil premium rate for additional FSI.
Playground mandatory for which school?
Playground mandatory for which school?
Pre-primary and nursery schools must provide a playground as per UDCPR.
Playground increase mandatory if FSI on upper floors?
Playground increase mandatory if FSI on upper floors?
Signup and view all the flashcards
Minimum playground area on vacant land?
Minimum playground area on vacant land?
Signup and view all the flashcards
Basic and additional FSI for Medical buildings?
Basic and additional FSI for Medical buildings?
Signup and view all the flashcards
Premium rate for private medical FSI?
Premium rate for private medical FSI?
Signup and view all the flashcards
Premium on FSI for Star Hotels?
Premium on FSI for Star Hotels?
Signup and view all the flashcards
Condition for Starred Hotels to avail FSI?
Condition for Starred Hotels to avail FSI?
Signup and view all the flashcards
Building potential for starred hotels is based on?
Building potential for starred hotels is based on?
Signup and view all the flashcards
% of FSI for tourism support?
% of FSI for tourism support?
Signup and view all the flashcards
Premium rates for institutions and banks?
Premium rates for institutions and banks?
Signup and view all the flashcards
Basic FSI for Government buildings?
Basic FSI for Government buildings?
Signup and view all the flashcards
Max potential for Govt. buildings on wide roads?
Max potential for Govt. buildings on wide roads?
Signup and view all the flashcards
Premium rate for Local Authorities?
Premium rate for Local Authorities?
Signup and view all the flashcards
Premium on FSI for PSUs?
Premium on FSI for PSUs?
Signup and view all the flashcards
Commercial use of FSI on MSRTC land?
Commercial use of FSI on MSRTC land?
Signup and view all the flashcards
% of land for MSRTC purpose?
% of land for MSRTC purpose?
Signup and view all the flashcards
Height regulatory compliance?
Height regulatory compliance?
Signup and view all the flashcards
Premium sharing in congested areas?
Premium sharing in congested areas?
Signup and view all the flashcards
Study Notes
Educational Buildings
- Additional FSI of up to 3.00 is permitted.
- Charitable educational institutions are exempt from premium charges.
- Pre-primary and nursery schools must provide a playground.
- Increasing FSI on upper floors of existing buildings does not mandate an increase in playground area.
- For vacant land, the minimum playground area should be 40% of the plot or the existing playground area, whichever is less.
Medical Buildings
- Basic FSI of 2.00 is allowed with an additional 3.00 FSI.
- Private medical institutions are subject to a 15% premium for additional FSI.
Star Category Hotels
- A maximum premium of 20% is levied on additional FSI.
- A certificate from the Tourism Department, GOI, is required to avail additional FSI.
- Building potential is determined based on the road width one step below that specified in Table 6-G.
Mega Tourism Projects
- 20% of the additional FSI may be utilized for tourism support activities.
Institutional Buildings and Banks
- Premium rates are per Sr. No. A or B depending on use.
Government and Semi-Government Buildings
- A basic FSI of 2.00 is permitted.
- Maximum building potential is 3.00 on roads ≥18 m width.
- Semi-Government buildings like Local Authorities are exempt from premium charges.
Public Sector Institutions
- A 15% premium applies to additional FSI.
MSRTC Land
- 2/3 of the FSI can be used for commercial purposes.
- At least 50% of the land must be used for the primary functions of MSRTC.
General Regulations
- Height regulations for educational and medical buildings must comply with UDCPR Table 6-A.
- In congested areas, the premium collected from higher FSI provisions is shared 50:50 between the Authority and the State Government.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.