Boiler Outlet Connections Quiz
15 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the purpose of outlet connections in a boiler?

  • To generate steam for the boiler
  • To increase the pressure inside the boiler
  • To connect the boiler to various controls, instruments, or fittings (correct)
  • To regulate the temperature of the boiler
  • How can fittings and piping be attached to the boiler?

  • Welded directly to the drum or shell (correct)
  • Connected with rubber bands
  • Attached with adhesive tape
  • Attached with velcro straps
  • What falls under the technical jurisdiction of ASME B31.1 Power Piping Code?

  • Boiler cleaning procedures
  • Boiler fuel consumption
  • Boiler external piping (correct)
  • Boiler exterior maintenance
  • According to ASME B31.1, what is required when two or more boilers are connected to a common header?

    <p>Fitting with two stop valves having an ample free-blow drain between them</p> Signup and view all the answers

    In Figure 6 described in ASME B31.1, what does Boiler #1 have?

    <p>A small steam drum and is only equipped with a handhole</p> Signup and view all the answers

    What is the purpose of the check valve in the feedwater piping for boilers?

    <p>To prevent the boiler from draining through the feedwater line when the boiler feedwater pump is not running.</p> Signup and view all the answers

    According to ASME B31.1, what type of valves are preferred for the required steam shut-off valves?

    <p>Outside screw and yoke, rising stem valves</p> Signup and view all the answers

    When two or more boilers are fed from a common source, what is required in the branch to each boiler?

    <p>Globe or regulating valve located between the check valve and the source of supply</p> Signup and view all the answers

    What is the required valve type for blowoff service according to ASME B31.1?

    <p>Y-type globe valves</p> Signup and view all the answers

    What is the rationale behind requiring slow-opening blowoff valves for boilers with allowable working pressures over 100 psig (690 kPag)?

    <p>To reduce wear on one valve by allowing it to operate in non-moving fluid</p> Signup and view all the answers

    What is the minimum pressure rating required for all valves or cocks in a boiler?

    <p>Not less than 120°C</p> Signup and view all the answers

    Why is it recommended to use outside screw and yoke valves with rising spindles for steam outlets DN 50 or larger?

    <p>To enable visibility of valve position from a distance</p> Signup and view all the answers

    Where should the feedwater connection be arranged to enter the boiler?

    <p>Internally using a pipe to direct the water to a suitable point</p> Signup and view all the answers

    What does ASME BPVC IV Part HG-705(a) state about introducing feedwater through openings or connections provided for inspection or cleaning, safety valve, water column, water gage glass, or pressure gage?

    <p>It should be avoided as it could affect the operation of feeders, cut-offs, or the safety valve</p> Signup and view all the answers

    Why is a check valve installed near the boiler in the feedwater pipe?

    <p>To prevent backflow and keep the boiler from draining when the boiler feedwater pump is off</p> Signup and view all the answers

    More Like This

    CSA B51 Boiler
    30 questions
    Ohio Boiler Test Flashcards
    100 questions

    Ohio Boiler Test Flashcards

    WellRegardedObsidian1129 avatar
    WellRegardedObsidian1129
    Boiler Systems and Safety Regulations
    60 questions
    Use Quizgecko on...
    Browser
    Browser