What is the primary purpose of using the BIOPAC bacteriologic filter in the procedure?
What is the primary purpose of using the BIOPAC bacteriologic filter in the procedure?
What should you do immediately after turning on the computer in the procedure?
What should you do immediately after turning on the computer in the procedure?
Which item is necessary to connect before launching the BIOPAC Student Lab program?
Which item is necessary to connect before launching the BIOPAC Student Lab program?
What is the significance of comparing VEMS values to ideal values during the experiment?
What is the significance of comparing VEMS values to ideal values during the experiment?
Signup and view all the answers
Which step involves the use of a specific side of the calibration syringe when mounting it on the transducer?
Which step involves the use of a specific side of the calibration syringe when mounting it on the transducer?
Signup and view all the answers
What should be done to enhance the accuracy of the respiratory cycle recording?
What should be done to enhance the accuracy of the respiratory cycle recording?
Signup and view all the answers
What is the purpose of pressing the 'Find volume' button after recording?
What is the purpose of pressing the 'Find volume' button after recording?
Signup and view all the answers
Which parameter indicates the time difference in the selected area of a respiratory recording?
Which parameter indicates the time difference in the selected area of a respiratory recording?
Signup and view all the answers
If the maximum exhalation is difficult to define, what is the recommended action?
If the maximum exhalation is difficult to define, what is the recommended action?
Signup and view all the answers
What sequence is suggested to follow for breathing during the recording?
What sequence is suggested to follow for breathing during the recording?
Signup and view all the answers
What is the first step in calibrating the equipment?
What is the first step in calibrating the equipment?
Signup and view all the answers
Why must the transducer be held vertically during calibration?
Why must the transducer be held vertically during calibration?
Signup and view all the answers
What happens during the second step of calibration regarding temperature and pressure?
What happens during the second step of calibration regarding temperature and pressure?
Signup and view all the answers
What should be done if the initial calibration does not result in an inverted deflection?
What should be done if the initial calibration does not result in an inverted deflection?
Signup and view all the answers
What posture should the participant maintain during the recording process?
What posture should the participant maintain during the recording process?
Signup and view all the answers
What is required for the equipment before the participant begins breathing normally for recordings?
What is required for the equipment before the participant begins breathing normally for recordings?
Signup and view all the answers
How should the syringe be held during the calibration step to avoid errors?
How should the syringe be held during the calibration step to avoid errors?
Signup and view all the answers
How many complete cycles are performed with the syringe during calibration?
How many complete cycles are performed with the syringe during calibration?
Signup and view all the answers
What is the purpose of the P-P value in the experiment?
What is the purpose of the P-P value in the experiment?
Signup and view all the answers
Which tool is used to select the area representing the complete forced expiration?
Which tool is used to select the area representing the complete forced expiration?
Signup and view all the answers
In section B, how should the selection tool be applied to track the exhaled volume?
In section B, how should the selection tool be applied to track the exhaled volume?
Signup and view all the answers
Which display settings are essential for viewing the graphical data correctly?
Which display settings are essential for viewing the graphical data correctly?
Signup and view all the answers
Which feature is NOT mentioned as part of the display settings?
Which feature is NOT mentioned as part of the display settings?
Signup and view all the answers
What is the main focus during the measurement of respiratory cycles?
What is the main focus during the measurement of respiratory cycles?
Signup and view all the answers
How long should the deep, rapid breathing phase last during the procedure?
How long should the deep, rapid breathing phase last during the procedure?
Signup and view all the answers
What should be done if the subject experiences dizziness during the procedure?
What should be done if the subject experiences dizziness during the procedure?
Signup and view all the answers
Which of the following tools is advised for analyzing rapid changes in respiratory cycles?
Which of the following tools is advised for analyzing rapid changes in respiratory cycles?
Signup and view all the answers
What is the recommended optimal respiration frequency during the procedure?
What is the recommended optimal respiration frequency during the procedure?
Signup and view all the answers
What range of time should be selected to count the cycles in the worksheet?
What range of time should be selected to count the cycles in the worksheet?
Signup and view all the answers
Which action should not be taken if an incomplete cycle is found at the end of the selection?
Which action should not be taken if an incomplete cycle is found at the end of the selection?
Signup and view all the answers
How many cycles should be approximately counted within the selected 12-second interval?
How many cycles should be approximately counted within the selected 12-second interval?
Signup and view all the answers
What is the primary purpose of marking the end of the selected area during the cycle selection process?
What is the primary purpose of marking the end of the selected area during the cycle selection process?
Signup and view all the answers
What should be monitored while selecting the interval for counting the cycles?
What should be monitored while selecting the interval for counting the cycles?
Signup and view all the answers
What is the correct sequence of actions to ensure the recording of respiratory function is accurate?
What is the correct sequence of actions to ensure the recording of respiratory function is accurate?
Signup and view all the answers
Which of the following statements about measuring DVMM (Vmax) is false?
Which of the following statements about measuring DVMM (Vmax) is false?
Signup and view all the answers
Which action is critical when selecting the 'Inlet' transducer end during the recording?
Which action is critical when selecting the 'Inlet' transducer end during the recording?
Signup and view all the answers
What duration of normal breathing is necessary before starting the recording?
What duration of normal breathing is necessary before starting the recording?
Signup and view all the answers
What should be done immediately after selecting the complete expiration for calculating CV?
What should be done immediately after selecting the complete expiration for calculating CV?
Signup and view all the answers
Study Notes
BIOPAC Calibration
- BIOPAC equipment calibration is a two-step process.
- The first step involves stabilizing the reference line with the transducer held vertically and immobile.
- The second step calibrates amplitude and compensates for temperature and pressure by passing a known volume of air through the transducer using a syringe.
- Five complete cycles with the syringe are performed, ending with the plunger fully retracted.
- The final calibration screen should match the one depicted in Figure 21.
- If an inverted deflection does not occur, change the transducer's orientation and repeat the calibration.
- Calibration should be performed only once, regardless of the number of participants.
Respiratory Function Recording
- The participant must sit, look in the direction opposite the monitor, be relaxed, and have their eyes closed to minimize any external disturbance.
- The participant places the nasal clip and secures the mouthpiece, and breathes normally through the apparatus for at least twenty seconds before starting the recording.
- Participants always breathe through the adapter marked "Inlet."
- The transducer must be held steady throughout the entire recording.
- A respiratory cycle consists of inspiration and expiration.
- Click the "Record 12" button and breathe normally for 3 cycles, then inhale as deeply as possible, hold your breath for a moment, and exhale forcefully and rapidly.
- Then, exhale normally for 3 cycles.
- Press the "Stop" button, then the "Find volume" button.
- The recording should be similar to the one in Figure 24.
- Data can be modified if the procedure was not strictly followed.
Respiratory Cycle Measurement Recording
- The subject should sit, looking in the direction opposite the monitor, relax, and with their eyes closed.
- The subject should place the nasal clip and secure the mouth piece; and breathe normally through the device for at least 20 seconds before the recording starts.
- Always breathe through the "Inlet" transducer end.
- The transducer should be held upright throughout the recording.
- A respiratory cycle consists of inspiration and expiration.
Recording Procedure
- Press the "Record 12" button.
- Perform 5 normal breathing cycles.
- Perform deep rapid breathing for 12–15 seconds.
- Perform 5 normal breathing cycles.
- Press the "Stop" button, then "Find volume" button.
DVMM (Vmax) Recording Procedure
- Click on the button "Redo 12" to measure DVMM (Vmax).
- The subject should sit, looking in the direction opposite to the monitor, relax, and with their eyes closed.
- The subject should place the nasal clip and secure the mouth piece; and breathe normally through the device for at least 20 seconds before the recording starts.
- Always breathe through the "Inlet" transducer end.
- The transducer should be held upright throughout the recording.
DVMM (Vmax) Data Analysis
- Use the selection tool to select an interval of 12 seconds in which the cycles are counted (approximately 15 cycles, monitor the Delta T value).
- Mark the end of the selected area (click on the bottom part of the marker zone).
- Use the selection tool to select each cycle within the 12-second interval.
- If an incomplete cycle is found at the end, do not consider it.
- Read the p-p values for each cycle.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
This quiz covers the essential steps for calibrating BIOPAC equipment and proper techniques for recording respiratory function. It outlines the calibration process, including the use of a transducer and necessary participant guidelines. Test your knowledge on these critical procedures in physiological measurement.