BIOPAC Calibration and Respiratory Recording
38 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the primary purpose of using the BIOPAC bacteriologic filter in the procedure?

  • To ensure accurate flow rate measurements
  • To prevent contamination during measurements (correct)
  • To enhance the conductivity of the data acquisition system
  • To maintain temperature stability of the equipment
  • What should you do immediately after turning on the computer in the procedure?

  • Select 'Lesson 12' in the program
  • Connect the calibration syringe to the BIOPAC
  • Launch the BIOPAC Student Lab program
  • Ensure the BIOPAC MP30 unit is off (correct)
  • Which item is necessary to connect before launching the BIOPAC Student Lab program?

  • Windows computer
  • Single-use BIOPAC mouthpiece
  • BIOPAC flow transducer (correct)
  • BIOPAC calibration syringe
  • What is the significance of comparing VEMS values to ideal values during the experiment?

    <p>To evaluate pulmonary function relative to expected norms</p> Signup and view all the answers

    Which step involves the use of a specific side of the calibration syringe when mounting it on the transducer?

    <p>Mount the syringe on the side labeled 'Inlet'</p> Signup and view all the answers

    What should be done to enhance the accuracy of the respiratory cycle recording?

    <p>Ensure the transducer is held steady throughout the recording.</p> Signup and view all the answers

    What is the purpose of pressing the 'Find volume' button after recording?

    <p>To analyze the volume data from the recording.</p> Signup and view all the answers

    Which parameter indicates the time difference in the selected area of a respiratory recording?

    <p>Delta T (ΔT)</p> Signup and view all the answers

    If the maximum exhalation is difficult to define, what is the recommended action?

    <p>Press the 'Redo' button and repeat the recording.</p> Signup and view all the answers

    What sequence is suggested to follow for breathing during the recording?

    <p>Inhale deeply, hold, and exhale normally for 3 cycles.</p> Signup and view all the answers

    What is the first step in calibrating the equipment?

    <p>Stabilizing the reference line</p> Signup and view all the answers

    Why must the transducer be held vertically during calibration?

    <p>To maintain a stable reference line</p> Signup and view all the answers

    What happens during the second step of calibration regarding temperature and pressure?

    <p>Correction factors are calculated</p> Signup and view all the answers

    What should be done if the initial calibration does not result in an inverted deflection?

    <p>Change the orientation of the transducer and repeat</p> Signup and view all the answers

    What posture should the participant maintain during the recording process?

    <p>Sitting relaxed with eyes closed</p> Signup and view all the answers

    What is required for the equipment before the participant begins breathing normally for recordings?

    <p>Participant to secure the nasal clip and mouthpiece</p> Signup and view all the answers

    How should the syringe be held during the calibration step to avoid errors?

    <p>With both hands, kept horizontal</p> Signup and view all the answers

    How many complete cycles are performed with the syringe during calibration?

    <p>Five</p> Signup and view all the answers

    What is the purpose of the P-P value in the experiment?

    <p>To represent the vital capacity during the forced expiration.</p> Signup and view all the answers

    Which tool is used to select the area representing the complete forced expiration?

    <p>Selection tool 'l'</p> Signup and view all the answers

    In section B, how should the selection tool be applied to track the exhaled volume?

    <p>Select the first second, then include the next two seconds individually.</p> Signup and view all the answers

    Which display settings are essential for viewing the graphical data correctly?

    <p>Autoscale horizontal, Autoscale waveforms, Zoom Previous.</p> Signup and view all the answers

    Which feature is NOT mentioned as part of the display settings?

    <p>Vertical Scale Adjustment</p> Signup and view all the answers

    What is the main focus during the measurement of respiratory cycles?

    <p>Frequency of the respiration</p> Signup and view all the answers

    How long should the deep, rapid breathing phase last during the procedure?

    <p>12–15 seconds</p> Signup and view all the answers

    What should be done if the subject experiences dizziness during the procedure?

    <p>Immediately stop the procedure</p> Signup and view all the answers

    Which of the following tools is advised for analyzing rapid changes in respiratory cycles?

    <p>Zoom function on the instrument</p> Signup and view all the answers

    What is the recommended optimal respiration frequency during the procedure?

    <p>More than 60 breaths per minute (bpm)</p> Signup and view all the answers

    What range of time should be selected to count the cycles in the worksheet?

    <p>12 seconds</p> Signup and view all the answers

    Which action should not be taken if an incomplete cycle is found at the end of the selection?

    <p>Include it for cycle counting</p> Signup and view all the answers

    How many cycles should be approximately counted within the selected 12-second interval?

    <p>15 cycles</p> Signup and view all the answers

    What is the primary purpose of marking the end of the selected area during the cycle selection process?

    <p>For later identification of the selected area</p> Signup and view all the answers

    What should be monitored while selecting the interval for counting the cycles?

    <p>The Delta T value</p> Signup and view all the answers

    What is the correct sequence of actions to ensure the recording of respiratory function is accurate?

    <p>Sit quietly, close eyes, place nasal clip, and breathe normally for 20 seconds.</p> Signup and view all the answers

    Which of the following statements about measuring DVMM (Vmax) is false?

    <p>The subject should begin measurement immediately without prior normalization.</p> Signup and view all the answers

    Which action is critical when selecting the 'Inlet' transducer end during the recording?

    <p>Breathing through the 'Inlet' transducer ensures correct airflow direction.</p> Signup and view all the answers

    What duration of normal breathing is necessary before starting the recording?

    <p>Normal breathing must be maintained for at least 20 seconds.</p> Signup and view all the answers

    What should be done immediately after selecting the complete expiration for calculating CV?

    <p>Select the first second of forced expiration next.</p> Signup and view all the answers

    Study Notes

    BIOPAC Calibration

    • BIOPAC equipment calibration is a two-step process.
    • The first step involves stabilizing the reference line with the transducer held vertically and immobile.
    • The second step calibrates amplitude and compensates for temperature and pressure by passing a known volume of air through the transducer using a syringe.
    • Five complete cycles with the syringe are performed, ending with the plunger fully retracted.
    • The final calibration screen should match the one depicted in Figure 21.
    • If an inverted deflection does not occur, change the transducer's orientation and repeat the calibration.
    • Calibration should be performed only once, regardless of the number of participants.

    Respiratory Function Recording

    • The participant must sit, look in the direction opposite the monitor, be relaxed, and have their eyes closed to minimize any external disturbance.
    • The participant places the nasal clip and secures the mouthpiece, and breathes normally through the apparatus for at least twenty seconds before starting the recording.
    • Participants always breathe through the adapter marked "Inlet."
    • The transducer must be held steady throughout the entire recording.
    • A respiratory cycle consists of inspiration and expiration.
    • Click the "Record 12" button and breathe normally for 3 cycles, then inhale as deeply as possible, hold your breath for a moment, and exhale forcefully and rapidly.
    • Then, exhale normally for 3 cycles.
    • Press the "Stop" button, then the "Find volume" button.
    • The recording should be similar to the one in Figure 24.
    • Data can be modified if the procedure was not strictly followed.

    Respiratory Cycle Measurement Recording

    • The subject should sit, looking in the direction opposite the monitor, relax, and with their eyes closed.
    • The subject should place the nasal clip and secure the mouth piece; and breathe normally through the device for at least 20 seconds before the recording starts.
    • Always breathe through the "Inlet" transducer end.
    • The transducer should be held upright throughout the recording.
    • A respiratory cycle consists of inspiration and expiration.

    Recording Procedure

    • Press the "Record 12" button.
    • Perform 5 normal breathing cycles.
    • Perform deep rapid breathing for 12–15 seconds.
    • Perform 5 normal breathing cycles.
    • Press the "Stop" button, then "Find volume" button.

    DVMM (Vmax) Recording Procedure

    • Click on the button "Redo 12" to measure DVMM (Vmax).
    • The subject should sit, looking in the direction opposite to the monitor, relax, and with their eyes closed.
    • The subject should place the nasal clip and secure the mouth piece; and breathe normally through the device for at least 20 seconds before the recording starts.
    • Always breathe through the "Inlet" transducer end.
    • The transducer should be held upright throughout the recording.

    DVMM (Vmax) Data Analysis

    • Use the selection tool to select an interval of 12 seconds in which the cycles are counted (approximately 15 cycles, monitor the Delta T value).
    • Mark the end of the selected area (click on the bottom part of the marker zone).
    • Use the selection tool to select each cycle within the 12-second interval.
    • If an incomplete cycle is found at the end, do not consider it.
    • Read the p-p values for each cycle.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers the essential steps for calibrating BIOPAC equipment and proper techniques for recording respiratory function. It outlines the calibration process, including the use of a transducer and necessary participant guidelines. Test your knowledge on these critical procedures in physiological measurement.

    More Like This

    Use Quizgecko on...
    Browser
    Browser