What is a primary concern in cemented total hip arthroplasty regarding the longevity of the implant?
What is a primary concern in cemented total hip arthroplasty regarding the longevity of the implant?
- Micromechanisms of fatigue in bone cements (correct)
- Material strength of the cement
- Formation of osteolytic lesions
- Poor surgical technique
Which factor is considered a significant mode of failure for cemented femoral components?
Which factor is considered a significant mode of failure for cemented femoral components?
- Excessive wear of the polyethylene
- Radiographic evidence of loosening (correct)
- Uncontrolled movement of the joint
- Bone growth into the implant
What differentiates uncemented total hip arthroplasty from cemented techniques?
What differentiates uncemented total hip arthroplasty from cemented techniques?
- The type of materials used
- The use of bone cements
- The surgical approach
- The nature of the implant fixation (correct)
Which biomaterial is noted for its increasing use in total hip replacement due to its favorable properties?
Which biomaterial is noted for its increasing use in total hip replacement due to its favorable properties?
What is a potential consequence of poor cementing techniques in total hip replacement surgery?
What is a potential consequence of poor cementing techniques in total hip replacement surgery?
In the context of hip arthroplasty, what does the term 'osteolysis' refer to?
In the context of hip arthroplasty, what does the term 'osteolysis' refer to?
Which of the following is a common postoperative outcome for patients receiving total hip arthroplasty?
Which of the following is a common postoperative outcome for patients receiving total hip arthroplasty?
What is considered a critical factor in ensuring the stability of the femoral stem during total hip arthroplasty?
What is considered a critical factor in ensuring the stability of the femoral stem during total hip arthroplasty?
What is the primary material used for prosthetic stabilization in cemented hip arthroplasty?
What is the primary material used for prosthetic stabilization in cemented hip arthroplasty?
What initiates aseptic loosening in cemented hip replacements?
What initiates aseptic loosening in cemented hip replacements?
Which of the following best describes the concept of cement interdigitation in bone stabilization?
Which of the following best describes the concept of cement interdigitation in bone stabilization?
What are wear particles from acetabular polyethylene primarily responsible for?
What are wear particles from acetabular polyethylene primarily responsible for?
Which mechanism of failure involves subsidence of the stem or cement into the femur?
Which mechanism of failure involves subsidence of the stem or cement into the femur?
How deep can loss of cement mantle proximally occur in cemented hip replacements?
How deep can loss of cement mantle proximally occur in cemented hip replacements?
What is the primary factor contributing to endosteal necrosis during initial cementing?
What is the primary factor contributing to endosteal necrosis during initial cementing?
What characteristic of bone contributes to its mechanical properties being greater in one direction than another?
What characteristic of bone contributes to its mechanical properties being greater in one direction than another?
Which mechanism of cemented component failure involves a varus positioned stem failing at specific areas?
Which mechanism of cemented component failure involves a varus positioned stem failing at specific areas?
Which type of wear involves particles being removed from a softer material and deposited within a joint space?
Which type of wear involves particles being removed from a softer material and deposited within a joint space?
What phenomenon occurs in bone when subjected to a constant load for an extended period, leading to gradual deformation?
What phenomenon occurs in bone when subjected to a constant load for an extended period, leading to gradual deformation?
What type of wear is primarily caused by particles entrapped between two contacting surfaces?
What type of wear is primarily caused by particles entrapped between two contacting surfaces?
What is the term for the condition where bone continues to deform at decreasing rates under a constant load?
What is the term for the condition where bone continues to deform at decreasing rates under a constant load?
Which bearing surface type has gained popularity due to significantly lower wear rates?
Which bearing surface type has gained popularity due to significantly lower wear rates?
What structural characteristic of bone allows it to have different mechanical properties in various directions?
What structural characteristic of bone allows it to have different mechanical properties in various directions?
What effect does applying a modest force rapidly have on bone compared to applying a higher force slowly?
What effect does applying a modest force rapidly have on bone compared to applying a higher force slowly?
Flashcards
Stress Shielding
Stress Shielding
A phenomenon where a load-bearing implant reduces the stress on surrounding bone, potentially leading to bone resorption and implant loosening.
Total Hip Arthroplasty
Total Hip Arthroplasty
A surgical procedure to replace a diseased hip joint with an artificial joint.
Cement Fixation
Cement Fixation
A method of implant fixation in which a bone cement is used to attach the implant to the bone.
Bone Resorption
Bone Resorption
Signup and view all the flashcards
Implant Loosening
Implant Loosening
Signup and view all the flashcards
Femoral Component
Femoral Component
Signup and view all the flashcards
Bone Tissue Physical Properties
Bone Tissue Physical Properties
Signup and view all the flashcards
Osteolysis
Osteolysis
Signup and view all the flashcards
Viscoelastic Material
Viscoelastic Material
Signup and view all the flashcards
Hysteresis
Hysteresis
Signup and view all the flashcards
Anisotropic Material
Anisotropic Material
Signup and view all the flashcards
Creep
Creep
Signup and view all the flashcards
Stress Relaxation
Stress Relaxation
Signup and view all the flashcards
Strain Rate
Strain Rate
Signup and view all the flashcards
Abrasive Wear
Abrasive Wear
Signup and view all the flashcards
Adhesive Wear
Adhesive Wear
Signup and view all the flashcards
Aseptic Loosening
Aseptic Loosening
Signup and view all the flashcards
Wear Particles
Wear Particles
Signup and view all the flashcards
Cement Stabilization
Cement Stabilization
Signup and view all the flashcards
Cement Interdigitation
Cement Interdigitation
Signup and view all the flashcards
Cementing Trauma
Cementing Trauma
Signup and view all the flashcards
Cement Failure Mechanisms
Cement Failure Mechanisms
Signup and view all the flashcards
Gruen's Classification
Gruen's Classification
Signup and view all the flashcards
Study Notes
Basic Science Considerations in Primary Total Hip Replacement
- Total Hip Replacement (THR) is a common operation, with numbers expected to rise due to aging population
- Many prosthesis options exist, making selection challenging; understanding basic scientific principles is essential
- Relevant joint anatomy includes the ball-and-socket structure of the hip, with key angular relationships (neck shaft angle, femoral anteversion, femoral offset) crucial for THR
- Femoral head diameter averages 46mm
- Neck shaft angle averages 130 degrees
- Femoral anteversion angle averages 12 degrees
- Femoral neck version is in relation to the intercondylar plane
- Femoral offset is critical for limb length and stability
- Individual variations and conditions affect these factors
- Biomechanical considerations involve flexion/extension, abduction/adduction, internal/external rotation
- The hip joint withstands cyclical loads, equivalent to 3-6 times body weight due to abductor contractions
- Peak loading can reach 7-8 times body weight during activities
- Forces on femoral head equal and opposite forces on acetabulum
- Abductor muscles provide two thirds of the hip joint force, maintaining hip stability
Material and Structural Properties
- Young's modulus describes stiffness (stress/strain), crucial for artificial materials used in THR
- Bone material is viscoelastic and anisotropic
- Bone exhibits creep and stress relaxation
Basic Types of Total Hip Arthroplasty
- Cemented components use PMMA cement to fix the implant into bone
- Cemented implants cause thermal and chemical trauma during implantation
- Cemented implants have limited remodeling potential
- Uncemented components favour bone ingrowth or on-growth onto the implant via porous coating or grit blasting
- Cementless components provide a greater degree of biologic integration with bone
Mechanisms of Wear in THR Bearings
- Wear occurs from abrasive wear (two surfaces with different hardness), adhesive wear (shearing of particles in PE articulations), and third-body wear (particles trapped between surfaces causing further wear)
- Wear particles contribute to aseptic loosening and osteolysis in the joint
Aseptic Loosening and Osteolysis
- Wear particles, especially from polyethylene, stimulate macrophage and histiocytic response, leading to osteolysis
- Aseptic loosening can be due to mechanical factors (cyclical loading, impingement)
- Biologial factors contribute to further loosening
Concept of Effective Joint Space (EJS)
- Understanding the entire volumetric area within a hip arthroplasty construct is critical, as wear particles and related inflammatory response can potentially cause osteolysis throughout the region
Discussion
- Cemented fixation techniques have evolved toward improved cement strength, reduced porosity and increased distal plugging
- Advanced cementing techniques aim to improve bone-cement interface
- Uncemented designs encourage bone ingrowth, enhancing the longevity
- Uncemented components should fill at least 90% of the host bone canal
- The optimal fit is usually determined through various navigation technologies and intraoperative templating
- Modular designs provide more flexibility in adjusting for individual anatomy in revision surgeries, but may increase the complexity of the issue in both design and function
Custom Designs
- Customized designs are often used in revision surgeries with significant anatomic variations
- 3-D modelling and computer aided design (CAD/CAM) can aid in creating implants to better fit the individual's anatomy
- Custom designs provide great potential for stability and bone preservation in revision cases
Future of Total Hip Arthroplasty
- The focus in future THRs is extending implant durability and survivorship in younger, more active patients
- Minimally invasive approaches are being investigated to reduce surgical trauma and improve patient recovery, but potential concerns about instability, bone defects, and neural damage need to be considered.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
This quiz covers essential scientific principles related to Total Hip Replacement (THR), including joint anatomy and biomechanical considerations. Understand key factors like angular relationships and femoral dimensions that are critical for successful hip surgery. Test your knowledge on these important aspects of orthopedics.