Basic Science in Total Hip Replacement
24 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is a primary concern in cemented total hip arthroplasty regarding the longevity of the implant?

  • Micromechanisms of fatigue in bone cements (correct)
  • Material strength of the cement
  • Formation of osteolytic lesions
  • Poor surgical technique
  • Which factor is considered a significant mode of failure for cemented femoral components?

  • Excessive wear of the polyethylene
  • Radiographic evidence of loosening (correct)
  • Uncontrolled movement of the joint
  • Bone growth into the implant
  • What differentiates uncemented total hip arthroplasty from cemented techniques?

  • The type of materials used
  • The use of bone cements
  • The surgical approach
  • The nature of the implant fixation (correct)
  • Which biomaterial is noted for its increasing use in total hip replacement due to its favorable properties?

    <p>Alumina ceramics</p> Signup and view all the answers

    What is a potential consequence of poor cementing techniques in total hip replacement surgery?

    <p>Higher incidence of component loosening</p> Signup and view all the answers

    In the context of hip arthroplasty, what does the term 'osteolysis' refer to?

    <p>Bone loss due to biological reactions</p> Signup and view all the answers

    Which of the following is a common postoperative outcome for patients receiving total hip arthroplasty?

    <p>Long-term satisfactory function</p> Signup and view all the answers

    What is considered a critical factor in ensuring the stability of the femoral stem during total hip arthroplasty?

    <p>The geometry of the implant</p> Signup and view all the answers

    What is the primary material used for prosthetic stabilization in cemented hip arthroplasty?

    <p>Polymethylmetacrylate (PMMA)</p> Signup and view all the answers

    What initiates aseptic loosening in cemented hip replacements?

    <p>Mechanical factors including cyclical loading</p> Signup and view all the answers

    Which of the following best describes the concept of cement interdigitation in bone stabilization?

    <p>Cement acting as grout without a true adhesive bond</p> Signup and view all the answers

    What are wear particles from acetabular polyethylene primarily responsible for?

    <p>Inducing macrophage and histiocytic response leading to osteolysis</p> Signup and view all the answers

    Which mechanism of failure involves subsidence of the stem or cement into the femur?

    <p>Pistoning</p> Signup and view all the answers

    How deep can loss of cement mantle proximally occur in cemented hip replacements?

    <p>500 micrometres</p> Signup and view all the answers

    What is the primary factor contributing to endosteal necrosis during initial cementing?

    <p>All of the above</p> Signup and view all the answers

    What characteristic of bone contributes to its mechanical properties being greater in one direction than another?

    <p>Anisotropy</p> Signup and view all the answers

    Which mechanism of cemented component failure involves a varus positioned stem failing at specific areas?

    <p>Medial midstem pivot</p> Signup and view all the answers

    Which type of wear involves particles being removed from a softer material and deposited within a joint space?

    <p>Abrasive wear</p> Signup and view all the answers

    What phenomenon occurs in bone when subjected to a constant load for an extended period, leading to gradual deformation?

    <p>Creep</p> Signup and view all the answers

    What type of wear is primarily caused by particles entrapped between two contacting surfaces?

    <p>Third-body wear</p> Signup and view all the answers

    What is the term for the condition where bone continues to deform at decreasing rates under a constant load?

    <p>Creep</p> Signup and view all the answers

    Which bearing surface type has gained popularity due to significantly lower wear rates?

    <p>Ceramic-on-ceramic</p> Signup and view all the answers

    What structural characteristic of bone allows it to have different mechanical properties in various directions?

    <p>Alignment of collagen fibrils</p> Signup and view all the answers

    What effect does applying a modest force rapidly have on bone compared to applying a higher force slowly?

    <p>It can lead to fracture.</p> Signup and view all the answers

    Study Notes

    Basic Science Considerations in Primary Total Hip Replacement

    • Total Hip Replacement (THR) is a common operation, with numbers expected to rise due to aging population
    • Many prosthesis options exist, making selection challenging; understanding basic scientific principles is essential
    • Relevant joint anatomy includes the ball-and-socket structure of the hip, with key angular relationships (neck shaft angle, femoral anteversion, femoral offset) crucial for THR
    • Femoral head diameter averages 46mm
    • Neck shaft angle averages 130 degrees
    • Femoral anteversion angle averages 12 degrees
    • Femoral neck version is in relation to the intercondylar plane
    • Femoral offset is critical for limb length and stability
    • Individual variations and conditions affect these factors
    • Biomechanical considerations involve flexion/extension, abduction/adduction, internal/external rotation
    • The hip joint withstands cyclical loads, equivalent to 3-6 times body weight due to abductor contractions
    • Peak loading can reach 7-8 times body weight during activities
    • Forces on femoral head equal and opposite forces on acetabulum
    • Abductor muscles provide two thirds of the hip joint force, maintaining hip stability

    Material and Structural Properties

    • Young's modulus describes stiffness (stress/strain), crucial for artificial materials used in THR
    • Bone material is viscoelastic and anisotropic
    • Bone exhibits creep and stress relaxation

    Basic Types of Total Hip Arthroplasty

    • Cemented components use PMMA cement to fix the implant into bone
    • Cemented implants cause thermal and chemical trauma during implantation
    • Cemented implants have limited remodeling potential
    • Uncemented components favour bone ingrowth or on-growth onto the implant via porous coating or grit blasting
    • Cementless components provide a greater degree of biologic integration with bone

    Mechanisms of Wear in THR Bearings

    • Wear occurs from abrasive wear (two surfaces with different hardness), adhesive wear (shearing of particles in PE articulations), and third-body wear (particles trapped between surfaces causing further wear)
    • Wear particles contribute to aseptic loosening and osteolysis in the joint

    Aseptic Loosening and Osteolysis

    • Wear particles, especially from polyethylene, stimulate macrophage and histiocytic response, leading to osteolysis
    • Aseptic loosening can be due to mechanical factors (cyclical loading, impingement)
    • Biologial factors contribute to further loosening

    Concept of Effective Joint Space (EJS)

    • Understanding the entire volumetric area within a hip arthroplasty construct is critical, as wear particles and related inflammatory response can potentially cause osteolysis throughout the region

    Discussion

    • Cemented fixation techniques have evolved toward improved cement strength, reduced porosity and increased distal plugging
    • Advanced cementing techniques aim to improve bone-cement interface
    • Uncemented designs encourage bone ingrowth, enhancing the longevity
    • Uncemented components should fill at least 90% of the host bone canal
    • The optimal fit is usually determined through various navigation technologies and intraoperative templating
    • Modular designs provide more flexibility in adjusting for individual anatomy in revision surgeries, but may increase the complexity of the issue in both design and function

    Custom Designs

    • Customized designs are often used in revision surgeries with significant anatomic variations
    • 3-D modelling and computer aided design (CAD/CAM) can aid in creating implants to better fit the individual's anatomy
    • Custom designs provide great potential for stability and bone preservation in revision cases

    Future of Total Hip Arthroplasty

    • The focus in future THRs is extending implant durability and survivorship in younger, more active patients
    • Minimally invasive approaches are being investigated to reduce surgical trauma and improve patient recovery, but potential concerns about instability, bone defects, and neural damage need to be considered.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers essential scientific principles related to Total Hip Replacement (THR), including joint anatomy and biomechanical considerations. Understand key factors like angular relationships and femoral dimensions that are critical for successful hip surgery. Test your knowledge on these important aspects of orthopedics.

    More Like This

    Use Quizgecko on...
    Browser
    Browser