Auxiliary Circuits in WAP5 and WAG9 Locomotives
76 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the main purpose of the machine room blowers in the auxiliary circuit?

  • To provide ventilation to the locomotive's exterior.
  • To operate the auxiliary motors in the locomotive.
  • To cool electronic cubicles and pressurize the machine room. (correct)
  • To increase the voltage of the main transformer.
  • What voltage does the auxiliary transformer output to the single phase circuit?

  • 1000V AC
  • 50V DC
  • 230V AC only
  • 415V AC and 110V AC (correct)
  • Which component of the auxiliary circuit is responsible for providing a cooling function during high temperatures?

  • The machine room blowers (correct)
  • The cab heaters
  • The 3-phase static auxiliary converter
  • The auxiliary transformer
  • How does the 3-phase auxiliary converter differ from the Arno Converter?

    <p>It is more maintenance-free with fewer moving parts.</p> Signup and view all the answers

    What occurs if the machine room temperature exceeds 70°C?

    <p>The machine room blower will activate to lower the temperature.</p> Signup and view all the answers

    What is the typical operating voltage of the auxiliary winding from the main transformer?

    <p>1000V</p> Signup and view all the answers

    What type of loads are connected to the 110V AC circuit in the single phase auxiliary circuit?

    <p>Blowers for cab heater and cab fans</p> Signup and view all the answers

    What advantage does the load distribution among the Bur's provide in the auxiliary circuit?

    <p>Automatic load switching to provide redundancy.</p> Signup and view all the answers

    What type of motors does the 3-phase auxiliary circuit provide power for?

    <p>3-phase auxiliary motors</p> Signup and view all the answers

    What is one of the primary functions of the cab heaters in the auxiliary circuit?

    <p>To ensure passenger comfort during travel.</p> Signup and view all the answers

    What is the maximum frequency limit for ventilation when BUR1 fails?

    <p>42Hz</p> Signup and view all the answers

    Which component is fed by BUR3 at a fixed frequency of 50Hz?

    <p>Battery charger</p> Signup and view all the answers

    How does the speed of the traction motor blowers vary?

    <p>It varies in three steps: 17Hz, 33Hz, and 50Hz.</p> Signup and view all the answers

    What happens to BUR3's output voltage and frequency when a compressor starts?

    <p>They are reduced to near zero before ramping up.</p> Signup and view all the answers

    What occurs if both BUR1 and BUR2 fail?

    <p>Ventilation is managed by BUR3 at 42Hz.</p> Signup and view all the answers

    Which contactors are closed when BUR1 is isolated?

    <p>Contactors 52/4, 52/1, 52/3, and 52.1/2</p> Signup and view all the answers

    What type of supply does BUR1&2 provide to the traction motor blowers?

    <p>Variable voltage and variable frequency supply</p> Signup and view all the answers

    What auxiliary function does BUR3 perform related to battery management?

    <p>It also supplies to battery chargers.</p> Signup and view all the answers

    What mechanism aids in load changeover between auxiliary converters during isolation?

    <p>Electro-pneumatic contactors</p> Signup and view all the answers

    What is the general operating frequency of BUR3?

    <p>50Hz</p> Signup and view all the answers

    What is the primary distinction between the single phase and 3-phase auxiliary circuits in the locomotives?

    <p>They have distinctly separated circuits despite being fed from the same auxiliary winding.</p> Signup and view all the answers

    How does the static auxiliary converter's operation differ fundamentally from that of a conventional Arno Converter?

    <p>It does not use rotating parts, leading to less wear and tear.</p> Signup and view all the answers

    What function do the scavenge blowers serve in the auxiliary circuit of the locomotives?

    <p>They assist in cooling electronic components within the machine room.</p> Signup and view all the answers

    In the case of a failure of any auxiliary converter, what ensures required redundancy within the auxiliary circuit?

    <p>The automatic load switching from one auxiliary converter to another.</p> Signup and view all the answers

    What operational strategy is implemented to prevent the machine room temperature from exceeding 70°C during peak summer?

    <p>The control circuit enters a 'cooling mode' allowing specific functions to operate without intervention.</p> Signup and view all the answers

    What role do the machine room blowers play during the locomotive's operation?

    <p>They prevent the overheating of electronic components by ensuring proper ventilation.</p> Signup and view all the answers

    What is the purpose of the 415V AC circuit within the single phase auxiliary circuit?

    <p>To supply energy to machine room blowers, scavenge blowers, and cab heaters.</p> Signup and view all the answers

    When does the machine room blower activate to lower the temperature in emergency situations?

    <p>When the control electronics indicate an over-temperature condition.</p> Signup and view all the answers

    What type of loads are primarily serviced by the 110V AC circuit in the single phase auxiliary circuit?

    <p>Heating elements and fans for cab trailers.</p> Signup and view all the answers

    How are the auxiliary circuits energized in the WAP5 and WAG9 locomotives?

    <p>Immediately after the circuit breaker is closed.</p> Signup and view all the answers

    What is the primary role of BUR3 in the auxiliary circuit?

    <p>To provide a fixed frequency supply to compressor motors and oil pumps</p> Signup and view all the answers

    What occurs to BUR3's voltage and frequency during the start of a compressor?

    <p>They drop to near zero and then ramp up for a soft start</p> Signup and view all the answers

    What limitation is placed on BUR1 and BUR2 when one of them fails?

    <p>They can only supply power to ventilation auxiliaries at 42Hz</p> Signup and view all the answers

    How does the auxiliary converter electronics respond during isolation of one converter?

    <p>It automatically switches the load to another auxiliary converter</p> Signup and view all the answers

    Which contactors remain closed when BUR2 is isolated?

    <p>52/5, 52/4, 52/3, 52.1/2</p> Signup and view all the answers

    What is the maximum frequency BUR2 can provide for ventilation when BUR1 fails?

    <p>42Hz</p> Signup and view all the answers

    What is the effect on BUR3 if it gets isolated?

    <p>BUR2 takes over feeding compressor motors at 50Hz</p> Signup and view all the answers

    What are the operating frequencies for the traction motor blowers controlled by BUR1 and BUR2?

    <p>17Hz, 33Hz, 50Hz</p> Signup and view all the answers

    What happens to the output voltage of BUR3 during normal operation?

    <p>It remains stable at 415V with slight variations</p> Signup and view all the answers

    What connections are made when BUR1 is isolated?

    <p>52/4, 52/1, 52/3, 52.1/2 are closed</p> Signup and view all the answers

    What is the maximum frequency BUR1 can provide for ventilation if BUR2 fails?

    <p>42Hz</p> Signup and view all the answers

    Which components does BUR3 feed with a fixed frequency supply?

    <p>Compressor motors</p> Signup and view all the answers

    What happens to BUR3's output voltage and frequency upon starting a compressor?

    <p>It drops to near zero.</p> Signup and view all the answers

    How does load changeover between auxiliary converters occur?

    <p>Automatically by the auxiliary converter electronics.</p> Signup and view all the answers

    What is the speed control mechanism for the traction motor blowers?

    <p>Three-step control based on temperature.</p> Signup and view all the answers

    What happens if BUR3 fails?

    <p>BUR2 feeds compressor motor and oil pumps at 50Hz.</p> Signup and view all the answers

    How is the speed of the traction motor blowers adjusted?

    <p>By control electronics based on temperature.</p> Signup and view all the answers

    What is the operating frequency of BUR3?

    <p>50Hz</p> Signup and view all the answers

    What is the role of contactors within the system during isolation events?

    <p>To facilitate automatic load changeover.</p> Signup and view all the answers

    Under normal operation, which contactors are closed?

    <p>52/1, 52/3, 52.½, 52/5</p> Signup and view all the answers

    What primary function do the machine room blowers serve?

    <p>To cool electronic cubicles and pressurize the machine room</p> Signup and view all the answers

    What is the maximum voltage output of the auxiliary transformer to the single phase circuit?

    <p>415V</p> Signup and view all the answers

    At what temperature must the machine room be maintained to ensure proper operation of control electronics?

    <p>70°C</p> Signup and view all the answers

    Which of the following is NOT a load connected to the 415V AC circuit?

    <p>Cab fans</p> Signup and view all the answers

    What characteristic sets the static auxiliary converter apart from the Arno Converter?

    <p>It is almost maintenance free due to no rotating parts</p> Signup and view all the answers

    How is redundancy achieved in the load distribution among the auxiliary converters?

    <p>By automatically switching load from one converter to another</p> Signup and view all the answers

    What voltage does the auxiliary transformer provide to the 110V AC circuit?

    <p>110V</p> Signup and view all the answers

    What is the primary benefit of the auxiliary circuit being distinctly separated for single phase and 3-phase machines?

    <p>Improved safety and operational reliability</p> Signup and view all the answers

    Which component in the auxiliary circuit is responsible for regulating the voltage output to auxiliary machines?

    <p>Static auxiliary converter</p> Signup and view all the answers

    What happens when the machine room blower is activated in high-temperature situations?

    <p>It aids in lowering the machine room temperature</p> Signup and view all the answers

    What is the maximum frequency that BUR1 or BUR2 can supply for ventilation when one of them fails?

    <p>42Hz</p> Signup and view all the answers

    What operational behavior occurs when a compressor is started with respect to BUR3?

    <p>Output voltage and frequency are reduced to near zero before ramping up.</p> Signup and view all the answers

    What is the primary function of the auxiliary transformer in the single phase circuit?

    <p>To convert 1000V AC to 415V and 110V AC</p> Signup and view all the answers

    In normal operation, which contactors are open?

    <p>52/2, 52/4, 52.1/1</p> Signup and view all the answers

    How is load changeover between auxiliary converters facilitated during isolation?

    <p>Automatically with the aid of electro-pneumatic contactors.</p> Signup and view all the answers

    Which of the following loads operate at 110V AC in the single phase auxiliary circuit?

    <p>Cab fans</p> Signup and view all the answers

    What action does the control circuit take when the machine room temperature exceeds 70°C?

    <p>It activates the machine room blowers in cooling mode</p> Signup and view all the answers

    What role does BUR3 play in feeding auxiliary components?

    <p>Supplies a fixed frequency to several critical components.</p> Signup and view all the answers

    What change happens to BUR2 and BUR1 when BUR3 fails?

    <p>BUR2 feeds compressor motor and oil pumps at a fixed frequency.</p> Signup and view all the answers

    What distinguishes the static auxiliary converter from conventional auxiliary converters?

    <p>It is less prone to mechanical wear and maintenance</p> Signup and view all the answers

    When do the 415V and 110V AC auxiliary circuits get energized?

    <p>As soon as the VCB is closed</p> Signup and view all the answers

    What action is taken by the control electronics for traction motor blowers based on temperature sensing?

    <p>They operate at one of three set frequencies.</p> Signup and view all the answers

    What aspect of BUR3's output voltage is influenced by the battery charging requirement?

    <p>It varies slightly around 415V.</p> Signup and view all the answers

    What is the main advantage of the load distribution among the BURs in the auxiliary circuit?

    <p>It allows for automatic load switching in case of converter failure</p> Signup and view all the answers

    What function do the scavenge blowers serve in the auxiliary circuit?

    <p>They assist the machine room blowers for effective cooling</p> Signup and view all the answers

    Which characteristic of the auxiliary converter electronics impacts maintenance efficiency?

    <p>Lack of moving components leading to low wear</p> Signup and view all the answers

    Study Notes

    Auxiliary Circuit Description

    • Auxiliary circuits in WAP5 and WAG9 locomotives use single-phase and three-phase motors. Circuits are separate but powered by the same auxiliary winding (1000V) of the main transformer.

    Single-Phase Circuit

    • Figure 5.1 shows the single-phase auxiliary circuit.
    • An auxiliary transformer steps down the auxiliary winding voltage to 415V and 110V AC.
    • The 415V AC circuit powers machine room blowers, scavenge blowers for machine room blowers, and cab heaters.
    • The 110V AC circuit powers cab fans and blowers for cab heaters.
    • Auxiliary circuits energize when the VCB is closed.
    • Machine room blowers cool electronic components and pressurize the machine room.
    • A target temperature of 70°C in the machine room is maintained.
    • If the temperature exceeds 70°C, a "cooling mode" operation is activated, allowing pantograph raising and VCB closure to bring the temperature back down. This happens automatically without operator intervention.

    Three-Phase Circuit

    • Figure 5.2 shows the three-phase auxiliary circuit.
    • WAP5 and WAG9 locomotives use static auxiliary converters.
    • These converters power three-phase auxiliary motors.
    • Static converters lack rotating components, leading to lower maintenance compared to Arno converters.

    Circuit Description

    • Load distribution among the converters ensures redundancy.
    • If one converter fails, the load automatically shifts to another.
    • This automatic switching occurs to maintain operation needed for the locomotive.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    Description

    This quiz focuses on the auxiliary circuits used in WAP5 and WAG9 locomotives, detailing both the single-phase and three-phase systems. It covers the functioning of these circuits, including the voltage step-down and temperature maintenance for optimal performance. Test your knowledge on locomotive auxiliary systems and their components.

    More Like This

    Mastering Auxiliary Verbs
    6 questions
    Mastering Auxiliary Verbs
    5 questions

    Mastering Auxiliary Verbs

    ForemostPinkTourmaline avatar
    ForemostPinkTourmaline
    Auxiliary Boilers Quiz
    6 questions

    Auxiliary Boilers Quiz

    WellInformedSelenite avatar
    WellInformedSelenite
    Exploring Auxiliary Control Interfaces in Human-Machine Interaction
    36 questions
    Use Quizgecko on...
    Browser
    Browser