Which fitting is required by ASME BPVC IV for every hot water heating boiler?
Which fitting is required by ASME BPVC IV for every hot water heating boiler?
What is the purpose of the stop valves in hot water heating boilers?
What is the purpose of the stop valves in hot water heating boilers?
Why are siphons not required between the gauge and the boiler in hot water service?
Why are siphons not required between the gauge and the boiler in hot water service?
Which fitting is covered in detail elsewhere in ASME BPVC IV, apart from safety relief valves, temperature controls, low water fuel cut-offs, and expansion tanks?
Which fitting is covered in detail elsewhere in ASME BPVC IV, apart from safety relief valves, temperature controls, low water fuel cut-offs, and expansion tanks?
Signup and view all the answers
What is the minimum hydrostatic test pressure required for a tank designed for a working pressure of 200 kPa or less?
What is the minimum hydrostatic test pressure required for a tank designed for a working pressure of 200 kPa or less?
Signup and view all the answers
For systems designed to operate above 200 kPa, what type of expansion tanks must be used?
For systems designed to operate above 200 kPa, what type of expansion tanks must be used?
Signup and view all the answers
What is a good practice for bladder-style expansion tanks, although not a requirement?
What is a good practice for bladder-style expansion tanks, although not a requirement?
Signup and view all the answers
What separates air bubbles from the water flow and directs them into the tank in the shown arrangement of a closed expansion tank?
What separates air bubbles from the water flow and directs them into the tank in the shown arrangement of a closed expansion tank?
Signup and view all the answers
Which type of expansion tanks bring air into direct contact with the water, potentially causing corrosion of steel piping and heating units?
Which type of expansion tanks bring air into direct contact with the water, potentially causing corrosion of steel piping and heating units?
Signup and view all the answers
What is used to allow draining of the tank without draining the system for bladder-style expansion tanks?
What is used to allow draining of the tank without draining the system for bladder-style expansion tanks?
Signup and view all the answers
What eliminates the problem of oxygen dissolving into the water in expansion tanks over time?
What eliminates the problem of oxygen dissolving into the water in expansion tanks over time?
Signup and view all the answers
Where is expansion tank operation and maintenance extensively covered?
Where is expansion tank operation and maintenance extensively covered?
Signup and view all the answers
What is the purpose of an expansion tank in a hot water heating system?
What is the purpose of an expansion tank in a hot water heating system?
Signup and view all the answers
What type of gauges are commonly combined into single gauges known as tridicator gauges?
What type of gauges are commonly combined into single gauges known as tridicator gauges?
Signup and view all the answers
What is the minimum reading for thermometers in hot water heating boilers?
What is the minimum reading for thermometers in hot water heating boilers?
Signup and view all the answers
In closed hot water heating systems, what should the pressure be in relation to altitude?
In closed hot water heating systems, what should the pressure be in relation to altitude?
Signup and view all the answers
What type of safety relief valve must be installed in each hot water heating boiler?
What type of safety relief valve must be installed in each hot water heating boiler?
Signup and view all the answers
Where should stop valves be placed in a hot water heating system?
Where should stop valves be placed in a hot water heating system?
Signup and view all the answers
What is the function of altitude gauges in hot water systems?
What is the function of altitude gauges in hot water systems?
Signup and view all the answers
Where should closed expansion tanks be connected in a hot water heating system?
Where should closed expansion tanks be connected in a hot water heating system?
Signup and view all the answers
What should additional safety relief valves be set to for boilers up to 400kPa?
What should additional safety relief valves be set to for boilers up to 400kPa?
Signup and view all the answers
What operating conditions are closed expansion tanks suitable for?
What operating conditions are closed expansion tanks suitable for?
Signup and view all the answers
What type of gauge is operated by bourdon tube assembly?
What type of gauge is operated by bourdon tube assembly?
Signup and view all the answers
Study Notes
- "Altitude" gauges in hot water systems are pressure gauges calibrated in terms of height of water, indicating system fullness.
- Gauges have two pointers: one operated by bourdon tube assembly, and another manually placed.
- In closed hot water heating systems, pressure should always be greater than altitude.
- Pressure and temperature gauges are commonly combined into single gauges, known as tridicator gauges.
- Hot water heating boilers must have a thermometer or temperature sensor, indicating temperature at or near boiler outlet.
- Thermometers must have a minimum reading of 20°C and a maximum reading of 160-205°C.
- Each hot water heating boiler must have at least one automatic reseating type safety relief valve, set to relieve at or below MAWP.
- Additional safety relief valves may be set to higher than MAWP, but not more than 40kPa for boilers up to 400kPa, or 5% for boilers exceeding 400kPa.
- Stop valves must be placed in supply and return pipe connections on all hot water heating boilers, allowing for drainage without emptying the entire system.
- Expansion tanks provide storage space for excess water due to expansion, preventing excessive pressure buildup.
- Closed expansion tanks can be used in systems with high operating temperatures and pressures, and are connected to supply main or top of boiler.
- An expansion tank must be installed that will be consistent with the volume and capacity of the system.