the approximate location of the main entrance doorknob, measured from the floor finish _____ meters
what is the minimum finish ceiling height at the second floor
what is the minimum width of two car carport if the space is not possible for 6 meters
what is the approximate height of each riser from the sidewalk to the house, in meters, if the maximum allowable height of riser and minimum setback required are applied?
Signup and view all the answers
what is the ideal width of the t&b door in meter
Signup and view all the answers
what code gorverns all electrical designs and installations
Signup and view all the answers
what code must be complied for all mechanical systems and/or equipment installation
Signup and view all the answers
how much will be the tax in percentage of design fee of the architect
Signup and view all the answers
what is the ideal spacing in meter of the 0.4mm thick metal ceiling frames when used in eaves ceiling
Signup and view all the answers
the most appropriate topcoat paint material for this projects exterior concrete wall is ___________________
Signup and view all the answers
what is the minimum thickness of a concrete footing in mm
Signup and view all the answers
what is the minimum depth of the footing below the surface of the ground in mm
Signup and view all the answers
what is the design live load in kilograms per sqm at ground floor
Signup and view all the answers
what is the compressive strength of slab in psi at second floor
Signup and view all the answers
what would be the approximate depth of the column in meters on this project
Signup and view all the answers
Study Notes
Building Design and Construction
- The main entrance doorknob is approximately located 0.9 meters from the floor finish.
Ceiling Heights
- The minimum finish ceiling height at the second floor is 2.4 meters.
Carport Dimensions
- The minimum width of a two-car carport is 5.5 meters if the 6-meter space is not possible.
Stairway Dimensions
- The approximate height of each riser from the sidewalk to the house is 0.15 meters, considering the maximum allowable height of the riser and minimum setback required.
Toilet and Bath (T&B) Door Dimensions
- The ideal width of the T&B door is 0.8 meters.
Electrical Design and Installation
- The code that governs all electrical designs and installations is the Philippine Electrical Code (PEC).
Mechanical Systems and Equipment Installation
- The code that must be complied with for all mechanical systems and equipment installations is the Philippine Mechanical Code (PMC).
Architect's Design Fee Tax
- The tax on the architect's design fee is 12% of the fee.
Metal Ceiling Frames
- The ideal spacing of 0.4mm thick metal ceiling frames in eaves ceiling is 1.2 meters.
Exterior Concrete Wall Finishing
- The most appropriate topcoat paint material for the project's exterior concrete wall is Acrylic Latex Paint.
Concrete Footing Dimensions
- The minimum thickness of a concrete footing is 150mm.
- The minimum depth of the footing below the surface of the ground is 150mm.
Live Load and Compressive Strength
- The design live load at the ground floor is 300 kilograms per square meter.
- The compressive strength of the slab at the second floor is 2,500 psi.
Column Depth
- The approximate depth of the column is 0.5 meters on this project.