project 1 - 2storey single attached 2bedroom house
15 Questions
3 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

the approximate location of the main entrance doorknob, measured from the floor finish _____ meters

  • 1
  • 1.20
  • 0.90 (correct)
  • 0.80
  • what is the minimum finish ceiling height at the second floor

  • 2400mm (correct)
  • 1800mm
  • 2700mm
  • 2250mm
  • what is the minimum width of two car carport if the space is not possible for 6 meters

  • 5.5m (correct)
  • 5.0m
  • 7.0m
  • 4.0m
  • what is the approximate height of each riser from the sidewalk to the house, in meters, if the maximum allowable height of riser and minimum setback required are applied?

    <p>0.20</p> Signup and view all the answers

    what is the ideal width of the t&b door in meter

    <p>0.70</p> Signup and view all the answers

    what code gorverns all electrical designs and installations

    <p>phil. electrial code</p> Signup and view all the answers

    what code must be complied for all mechanical systems and/or equipment installation

    <p>phil. mechanical code</p> Signup and view all the answers

    how much will be the tax in percentage of design fee of the architect

    <p>12%</p> Signup and view all the answers

    what is the ideal spacing in meter of the 0.4mm thick metal ceiling frames when used in eaves ceiling

    <p>0.60</p> Signup and view all the answers

    the most appropriate topcoat paint material for this projects exterior concrete wall is ___________________

    <p>latex</p> Signup and view all the answers

    what is the minimum thickness of a concrete footing in mm

    <p>250</p> Signup and view all the answers

    what is the minimum depth of the footing below the surface of the ground in mm

    <p>600</p> Signup and view all the answers

    what is the design live load in kilograms per sqm at ground floor

    <p>200</p> Signup and view all the answers

    what is the compressive strength of slab in psi at second floor

    <p>3500</p> Signup and view all the answers

    what would be the approximate depth of the column in meters on this project

    <p>0.30</p> Signup and view all the answers

    Study Notes

    Building Design and Construction

    • The main entrance doorknob is approximately located 0.9 meters from the floor finish.

    Ceiling Heights

    • The minimum finish ceiling height at the second floor is 2.4 meters.

    Carport Dimensions

    • The minimum width of a two-car carport is 5.5 meters if the 6-meter space is not possible.

    Stairway Dimensions

    • The approximate height of each riser from the sidewalk to the house is 0.15 meters, considering the maximum allowable height of the riser and minimum setback required.

    Toilet and Bath (T&B) Door Dimensions

    • The ideal width of the T&B door is 0.8 meters.

    Electrical Design and Installation

    • The code that governs all electrical designs and installations is the Philippine Electrical Code (PEC).

    Mechanical Systems and Equipment Installation

    • The code that must be complied with for all mechanical systems and equipment installations is the Philippine Mechanical Code (PMC).

    Architect's Design Fee Tax

    • The tax on the architect's design fee is 12% of the fee.

    Metal Ceiling Frames

    • The ideal spacing of 0.4mm thick metal ceiling frames in eaves ceiling is 1.2 meters.

    Exterior Concrete Wall Finishing

    • The most appropriate topcoat paint material for the project's exterior concrete wall is Acrylic Latex Paint.

    Concrete Footing Dimensions

    • The minimum thickness of a concrete footing is 150mm.
    • The minimum depth of the footing below the surface of the ground is 150mm.

    Live Load and Compressive Strength

    • The design live load at the ground floor is 300 kilograms per square meter.
    • The compressive strength of the slab at the second floor is 2,500 psi.

    Column Depth

    • The approximate depth of the column is 0.5 meters on this project.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    More Like This

    Project 1 (PRT152S) Introduction Quiz
    12 questions
    1.1.1 Project Constraints
    6 questions

    1.1.1 Project Constraints

    ViewableCaricature avatar
    ViewableCaricature
    ITE 1 - Project Management Overview
    29 questions
    Module 1: Project Management
    101 questions

    Module 1: Project Management

    OrganizedEmpowerment1022 avatar
    OrganizedEmpowerment1022
    Use Quizgecko on...
    Browser
    Browser