Engine ladder tactical Stjfd
30 Questions
5 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is a key objective regarding air management in a hazardous atmosphere?

  • To wait for the command to exit
  • To exit the atmosphere before the low air alarm activates (correct)
  • To ignore air levels completely
  • To activate the low air alarm once inside
  • When should air levels be checked?

  • Every ten minutes
  • When entering a new area or going to a new floor (correct)
  • Only when entering a building
  • Only when the low air alarm sounds
  • At what air cylinder capacity should firefighters consider transitioning out of operations?

  • 50% capacity (2250 PSI) (correct)
  • 75% capacity (3375 PSI)
  • 10% capacity (450 PSI)
  • 90% capacity (4050 PSI)
  • Which task is part of the engine company's tactical objectives?

    <p>Providing a water supply</p> Signup and view all the answers

    What is the primary consideration when given the assignment 'Exposures'?

    <p>Life safety and fire spread</p> Signup and view all the answers

    What is included in the size-up process?

    <p>Looking at as much of the structure as practical</p> Signup and view all the answers

    What tool combination should be selected to extinguish the fire?

    <p>Proper hoseline and nozzle</p> Signup and view all the answers

    Which action is part of confining the fire?

    <p>Placing a hoseline between the fire and any known occupants</p> Signup and view all the answers

    What should crew members maintain regarding their own status?

    <p>An ongoing awareness of their air status</p> Signup and view all the answers

    What should a company identify prior to entry?

    <p>An exit strategy</p> Signup and view all the answers

    What is the 1st priority for ladder companies?

    <p>Life Safety</p> Signup and view all the answers

    Which of the following is the 2nd priority for ladder companies?

    <p>Ventilation</p> Signup and view all the answers

    Which priority involves securing electricity, natural gas/propane, and water?

    <p>4th Priority</p> Signup and view all the answers

    What should ladder companies consider when determining their tactics?

    <p>All of the above</p> Signup and view all the answers

    Which priority should be given higher importance if the truck is used to prevent water damage in a sprinkler-controlled fire?

    <p>Salvage</p> Signup and view all the answers

    Which is NOT one of the priorities for ladder companies?

    <p>Public Relations</p> Signup and view all the answers

    Why should ladder companies perform a rapid risk benefit analysis?

    <p>To maximize life safety for all</p> Signup and view all the answers

    Forcible Entry is included in which priority?

    <p>3rd Priority</p> Signup and view all the answers

    Which is a factor to consider when assessing tactics for ladder companies?

    <p>Occupancy type</p> Signup and view all the answers

    In what situation should Salvage be prioritized higher?

    <p>Sprinkler-controlled fire</p> Signup and view all the answers

    What is the minimum number of firefighters needed to form a RIT team?

    <p>4 firefighters</p> Signup and view all the answers

    What is the primary priority for first-arriving engine companies?

    <p>Applying water in an efficient, effective, and safe manner</p> Signup and view all the answers

    What is one of the tasks not listed as a responsibility of engine companies during initial fire suppression operations?

    <p>Overhaul</p> Signup and view all the answers

    What does VEIS stand for in the context of ladder company tactical objectives?

    <p>Vent-Enter-Isolate-Search</p> Signup and view all the answers

    What is the main function of a Standby Team?

    <p>Immediate assistance or rescue of an entry team</p> Signup and view all the answers

    Which is not a method of ventilation conducted by Ladder Companies?

    <p>Indirect</p> Signup and view all the answers

    What should be benchmarked on the radio by Engine Companies?

    <p>Water Supply</p> Signup and view all the answers

    How many firefighters minimum are required for a Standby Team?

    <p>2 firefighters</p> Signup and view all the answers

    Which operation is most often accomplished during a primary search by Ladder Companies?

    <p>Search &amp; Rescue</p> Signup and view all the answers

    Which task is associated with the process of softening a structure during offensive operations?

    <p>Forcible Entry</p> Signup and view all the answers

    Study Notes

    Air Management

    • The objective is to avoid Hazardous Atmosphere/IDLH atmosphere before the low air alarm activation.
    • Crew members should maintain awareness of their air status and check air levels when entering a new area or floor.
    • Identify an exit strategy prior to entry and consider transitioning out of operations when air is at 50% cylinder capacity (2250 PSI).

    Tactical Objectives

    Engine Company Tactical Objectives

    • Size-up the situation and locate the fire, including assessing structure, smoke conditions, access, ventilation points, occupants, and hose lay.
    • Confine the fire by placing a hoseline between the fire and occupants.
    • Extinguish the fire with the proper hoseline and nozzle combination.
    • Protect exposures by eliminating fire extension and evacuating occupants.
    • Provide a water supply through hydrants, standpipes, and sprinkler systems.

    Water Supply

    • Establish a water supply, potentially requiring Rural Water Supply.

    RIT (Rapid Intervention Team)

    • A RIT team consists of at least 4 firefighters, including a company officer or acting company officer, to deal with rapid rescue situations.

    Engine Companies

    • Engine companies address the following during initial fire suppression:
      • Locate, confine, and extinguish the fire.
      • Conduct a rapid primary search of the fire room or unit.
      • Establish a water supply.
      • Protect exposures.
      • Implement Two-Out and RIT Team protocols.
    • Applying water efficiently and safely is a priority.

    Standby Team

    • A Standby Team is assigned prior to RIT establishment, consisting of at least two firefighters available for immediate assistance or rescue outside the hazard area.
    • Once relieved by RIT, the Standby Team can become a Backup Team.

    Ladder Company Tactical Objectives

    • Ladder company objectives include:
      • Search & Rescue, often during primary search or as part of VEIS.
      • Ventilation through various methods.
      • Ladder provision for access, egress, and rescue operations.
      • Forcible Entry, coordinated with command.
      • Overhaul, locating and mitigating hidden fire.
      • Salvage, saving property and reducing damage.

    Ladder Company Assignment by Priority

    • Priorities for Ladder Companies are:
      • 1st Priority: Life Safety
      • 2nd Priority: Ventilation
      • 3rd Priority: Forcible Entry and Ladders
      • 4th Priority: Utilities, Overhaul, and Salvage
      • Note: Salvage may be prioritized higher in certain situations, such as preventing water damage.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Learn about the importance of air management and safety procedures in hazardous environments. Understand how to maintain air status awareness and develop an exit strategy to ensure safe operations.

    More Like This

    202.05C Strategic Level Air Management:
    13 questions
    202.05C Tactical Level of Air Management
    13 questions
    6.2 Air Management
    29 questions

    6.2 Air Management

    WellBacklitTelescope avatar
    WellBacklitTelescope
    SCBA Air Management FOG
    15 questions

    SCBA Air Management FOG

    DevoutCharacterization6077 avatar
    DevoutCharacterization6077
    Use Quizgecko on...