Air Conditioning & AHU Systems

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson
Download our mobile app to listen on the go
Get App

Questions and Answers

Which combination of air qualities is directly managed by a comprehensive Air Conditioning (A/C) system?

  • Carbon dioxide level, Odor, Airflow
  • Airflow, Ozone concentration, Sound level
  • Dry bulb temperature, Cleanliness, Motion, Relative humidity (correct)
  • Particulate matter, Air pressure, Air speed

What defines a zone in the context of building climate control?

  • An area whose temperature is independently regulated by a thermostat. (correct)
  • A section of a building receiving uniform sunlight exposure.
  • An area with shared ductwork.
  • A space with consistent occupancy patterns.

Which of the following is a common type of comfort air conditioning system used in buildings?

  • District heating, absorption, desiccant
  • Solar-powered, evaporative, hybrid
  • All-air, all-water, direct refrigerant, air-water (correct)
  • Steam-based, radiant, geothermal

For what size application are centrifugal chillers typically suited?

<p>Applications requiring 100 to 30,000 tons of cooling (D)</p>
Signup and view all the answers

In a liquid chiller, what do the cooler and shell refer to?

<p>The evaporator and its surrounding casing (C)</p>
Signup and view all the answers

How is the condenser typically situated in relation to the cooler in a chiller system?

<p>It is above the cooler. (B)</p>
Signup and view all the answers

What is the common cooling medium used in a chiller to provide refrigeration?

<p>Water (D)</p>
Signup and view all the answers

Which of the following correctly lists the two main categories of chillers?

<p>Absorption cycle and compression cycle (B)</p>
Signup and view all the answers

What type of compressor is generally used with low-pressure chillers?

<p>Centrifugal (C)</p>
Signup and view all the answers

Which refrigerants are commonly associated with low-pressure centrifugal chillers?

<p>R11 and R123 (B)</p>
Signup and view all the answers

In an Air Handling Unit (AHU) classified as "draw-thru," where is the fan located?

<p>Downstream of the cooling coil, pushing air through it (A)</p>
Signup and view all the answers

What is the purpose of installing Air Handling Unit (AHU) casings downstream of the cooling coil?

<p>To prevent condensation on the panel (C)</p>
Signup and view all the answers

Which coil fin designs are commonly employed by CARRIER for Air Handling Units (AHU)?

<p>Plate and spiral (A)</p>
Signup and view all the answers

According to Carrier AHU information, what is the main advantage of fan capacity reduction in response to reduced load conditions?

<p>Resulting drive power input reductions can be realized (B)</p>
Signup and view all the answers

What is the primary function of face and bypass damper sections within an Air Handling Unit (AHU)?

<p>Permits air to bypass the cooling coil for part load control (A)</p>
Signup and view all the answers

In an HVAC system, what is the primary purpose of a mixing box?

<p>Provide the proper mixture of return and outside air for the space (B)</p>
Signup and view all the answers

What type of device is commonly used to modulate damper settings in HVAC systems?

<p>A pneumatic operator (B)</p>
Signup and view all the answers

Which type of air filter is generally considered the most efficient at removing particulate matter?

<p>HEPA (C)</p>
Signup and view all the answers

What is the main purpose of a multi-zone Air Handling Unit (AHU)?

<p>Heat and/or separate areas of building independently (C)</p>
Signup and view all the answers

What is a defining characteristic of a dual duct system?

<p>It incorporates separate ducts for hot and cold supply air. (D)</p>
Signup and view all the answers

Flashcards

Air qualities controlled by A/C

Dry bulb temperature, cleanliness, motion, and relative humidity.

What is a zone (control zone)?

Each area of a building with temperature separately controlled by a thermostat.

Basic comfort A/C systems types

All air, all water, direct refrigerant, and air water systems.

Cooler and shell (liquid chiller)

The evaporator and casing that surrounds it.

Signup and view all the flashcards

Condenser location (relative to cooler)

It is above the cooler

Signup and view all the flashcards

Two basic chiller categories

Absorption cycle and Compression cycle.

Signup and view all the flashcards

Compressor type (low pressure chillers)

Centrifugal.

Signup and view all the flashcards

Refrigerants (low pressure centrifugal chillers)

R11 and R123

Signup and view all the flashcards

Fan location (AHU "draw-thru")

Is located downstream of the cooling and pushes air through the coil.

Signup and view all the flashcards

Why AHU casings installed (downstream)

To prevent condensation on the panel.

Signup and view all the flashcards

Basic coil-fin designs (CARRIER AHU)

Plate and Spiral.

Signup and view all the flashcards

Purpose of bypass damper sections (AHU)

Permits air to bypass the cooling coil for part load control.

Signup and view all the flashcards

Purpose of mixing box

Provide the proper mixture of return and outside air for the space.

Signup and view all the flashcards

Device used to modulate damper settings

A pneumatic operator.

Signup and view all the flashcards

Purpose of multi-zone AHU

Heat and/or separate areas of building independently.

Signup and view all the flashcards

Dual duct system definition

Has separate hot and cold supply ducts run throughout the building.

Signup and view all the flashcards

Water cooled condenser advantages

They operate at a lower saturated condensing temperature.

Signup and view all the flashcards

Periodic cleaning of waterside importance

Keeps the system energy efficiency up.

Signup and view all the flashcards

Symptom indicating blocked/dirty

High head pressure.

Signup and view all the flashcards

Another name for head pressure control

Condenser capacity control.

Signup and view all the flashcards

Study Notes

  • Air conditioning systems control dry bulb temperature, cleanliness, and relative humidity
  • A zone is an area with temperature controlled by a thermostat
  • Basic types of comfort air conditioning include all air, all water, direct refrigerant, and air water systems
  • Centrifugal chillers are for 100 - 30,000 tons
  • A cooler and shell on a liquid chiller is the evaporator and casing
  • The condenser is above the cooler
  • Water is a cooling medium for chiller refrigeration
  • Two chiller categories include absorption and compression cycles
  • Centrifugal compressors are in low pressure chillers
  • R11 and R123 are refrigerants for low pressure centrifugal chillers
  • "Draw-thru" AHU fans are downstream, pushing air through the coil
  • AHU casings downstream of the cooling coil prevent condensation
  • CARRIER AHU coil fin designs include plate and spiral
  • Fan capacity reduction reduces drive power input, energy, and cost

AHU

  • AHU face and bypass dampers allow air to bypass the cooling coil for part load control
  • Mixing boxes mix return and outside air
  • Pneumatic operators modulate damper settings
  • HEPA filters are efficient air filters
  • Multi-zone AHUs heat/separate areas independently

Condensers

  • Dual duct systems have separate hot and cold supply ducts
  • Water cooled condensers offer better system efficiency due to lower saturated condensing temperature
  • Waterside cleaning of water cooled condensers maintains system energy efficiency
  • High head pressure usually indicates blockage
  • Head pressure control is also called condenser capacity control
  • Head pressure control systems maintain high side pressure as outdoor temperature decreases
  • Head Pressure control is needed when there is low cooling capacity at cool outdoor temperatures

Cooling Towers

  • Cooling towers in chilled water systems reject heat absorption
  • Water is spread out to enhance evaporation
  • Cooling towers require makeup water systems to replenish evaporated water
  • Blowdown relieves the mineral concentration in the sump water

Compressors

  • Minimum load is likely to cause compressor instability
  • Inlet vanes extend the compressor stability range
  • 3-stage centrifugal designs offer greater stability than single stage
  • Condensing pressure reduction extends compressor unloading range
  • A purge unit controls the amount of non-condensable gases and moisture
  • Surge causes include excessive head pressure and inadequate cooler pressure
  • Marine boxes assist condenser maintenance by providing easy access to clean tubes

Other

  • CenTraVac uses an orifice metering device
  • The trane CenTraVac cooler is a flooded type
  • Centrifugal compressors are used in low pressure chillers
  • 3-way valves allow coil control while maintaining constant system water flow rate
  • Decoupler systems balance chilled water production and pumping capacity with load
  • Condenser water temperature control allows condensing pressure to ride with load, increasing compressor modulating range
  • Assuming the leaving evaporator water temperature is 42F*, the minimum entering condenser water temperature 62F*
  • The design temperature CHW -10*
  • The design temperature CW -10*
  • A 4 pipe system can independently cool and heat separate zones
  • Materials for piping include black steel, hard copper, and plastics
  • Pipe sizing determines against what the pump must work
  • Excessive water velocity can cause noise and erosion
  • The preferred pump and motor RPM is 1750 RPM
  • Pump packing types include ring and mechanical
  • A decrease in head causes increased GPM & horsepower
  • Centrifugal pumps require discharge throttling valves because overestimating the system head needs a throttling valve to balance a flow to design GPM
  • Vortexing in a cooling tower causes a whirlpool type action
  • Pump/motor alignment types include angular and parallel
  • Condenser water pumps are generally centrifugal
  • Pump Cavitation will result if NPSHA is less than NPSHR, the suction valve is partially closed, the water source is too far below the inlet, or the strainer is clogged
  • Pump head is a force measure (units of feet) representing pump discharge
  • Pump head is calculated by multiplying PSI times 2.31, or dividing PSI by .433
  • Centrifugal pump types include horizontal split case and end suction
  • CW flow switches protect the condenser from high pressure
  • CHW flow switches protect the cooler from high pressure
  • Backflow preventers prevent potable water contamination
  • CW treatment control systems protect CW from scale and algae
  • Freeze thermostats protects CW and CHW systems by automatically starting the CW and CHW pumps?
  • Direct Action pneumatic thermostats create variable increases and output increases
  • The definition of Offset control is the amount of difference between the control point and set point in a proportional control system
  • Modulating control allows controlled devices to assume any position from fully closed to fully open
  • Controlled variables include temperature, humidity, and pressure
  • Spring range is the start point to finish point of an actuator

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Related Documents

More Like This

Air Conditioning Basics Quiz
3 questions
NFPA 90B: Heating and Air Conditioning
10 questions
Plant systems: Air Conditioning Systems
37 questions
Use Quizgecko on...
Browser
Browser