Accessibility Standards Quiz
37 Questions
0 Views

Accessibility Standards Quiz

Created by
@HospitableWatermelonTourmaline

Podcast Beta

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the standard temperature recommended for thermal comfort according to ASHRAE 55?

  • 80 degrees
  • 78 degrees
  • 70 degrees
  • 75 degrees (correct)
  • Which of the following is NOT a key factor to consider in system design?

  • Psychosocial Situation
  • Air Quality
  • Number of Occupants
  • Cost of Materials (correct)
  • How does relative humidity affect the perception of temperature in a space?

  • Humidity can cause spaces to feel warmer even at acceptable temperatures. (correct)
  • Lower temperatures are always preferred regardless of humidity levels.
  • Humidity has no impact on how temperature is perceived.
  • Higher humidity always makes the space feel colder.
  • Which of the following factors does NOT influence human comfort?

    <p>Cost of Operation</p> Signup and view all the answers

    What is the recommended relative humidity level for maintaining comfort according to ASHRAE 55?

    <p>50%</p> Signup and view all the answers

    What is the maximum high side reach for a depth of 10 inches?

    <p>48 inches</p> Signup and view all the answers

    What is the minimum clear width required for door openings?

    <p>32 inches</p> Signup and view all the answers

    What is the maximum force to push or pull open an interior hinged door?

    <p>5 pounds</p> Signup and view all the answers

    What is the maximum slope ratio for ramp runs?

    <p>1:12</p> Signup and view all the answers

    What is the minimum clear width between handrails on a ramp run?

    <p>36 inches</p> Signup and view all the answers

    What is the maximum rise for any ramp run?

    <p>30 inches</p> Signup and view all the answers

    How many functions does HVAC technology encompass?

    <p>Three: Heating, Ventilation, and Air Conditioning</p> Signup and view all the answers

    What is a criterion for continuous handrails on ramps?

    <p>Not required if serving aisles with seating</p> Signup and view all the answers

    What is the primary purpose of dehumidification in indoor environments?

    <p>To remove water vapor from the air</p> Signup and view all the answers

    What does ventilation aim to achieve in a conditioned space?

    <p>Remove gaseous contaminants</p> Signup and view all the answers

    Which process involves raising or maintaining the moisture content of the air?

    <p>Humidification</p> Signup and view all the answers

    Which of the following contributes to human comfort by moderating indoor air conditions?

    <p>All of the above</p> Signup and view all the answers

    What is one result of effective filtration in indoor air quality management?

    <p>Removal of particulate matter</p> Signup and view all the answers

    In the context of air conditioning, which term refers to the exchange of air between the indoors and outdoors?

    <p>Ventilation</p> Signup and view all the answers

    Which process helps to lower indoor humidity levels?

    <p>Dehumidification</p> Signup and view all the answers

    What is the main function of humidification in a conditioned space?

    <p>To add moisture to the air</p> Signup and view all the answers

    What is the primary function of a balancing damper in air distribution systems?

    <p>To regulate air flow into a space</p> Signup and view all the answers

    Which factor does NOT impact the overall sizing of ductwork?

    <p>Duct Color</p> Signup and view all the answers

    In what scenario should a horizontal fire damper be considered?

    <p>In vertical chases under certain conditions</p> Signup and view all the answers

    What is the required action for ventilation systems when a building is occupied?

    <p>To supply the required rate of ventilation air continuously</p> Signup and view all the answers

    Who determines the occupant load used for designing ventilation systems?

    <p>The estimated maximum occupant load rate indicated in Table 403.3</p> Signup and view all the answers

    When considering ventilation for non-smoking lounges, what is assumed about smoke presence?

    <p>The rates are based on the absence of smoking</p> Signup and view all the answers

    What is a smoke damper primarily used for?

    <p>To prevent smoke from being distributed to other parts of the building</p> Signup and view all the answers

    What general area should be avoided when running ductwork?

    <p>Stairs and elevators</p> Signup and view all the answers

    What determines the minimum ventilation rates in a building?

    <p>Occupancy Density</p> Signup and view all the answers

    How is the Total Fresh Air Required (Vbz) calculated for a classroom?

    <p>Adding the product of occupancy and a constant to the area multiplied by a constant</p> Signup and view all the answers

    What does ACH stand for in the context of air distribution?

    <p>Air Change Per Hour</p> Signup and view all the answers

    What is the formula to calculate total airflow in cubic feet per hour (cfh)?

    <p>Volume of Space x Air Changes Per Hour</p> Signup and view all the answers

    What does CFM stand for in air distribution?

    <p>Cubic Feet per Minute</p> Signup and view all the answers

    Which of the following is NOT a factor that affects the sizing criteria of air distribution ductwork?

    <p>Humidity levels</p> Signup and view all the answers

    What is the maximum allowable length for flexible ductwork?

    <p>6 feet</p> Signup and view all the answers

    What must be included in ductwork clearances?

    <p>2 inches for insulation</p> Signup and view all the answers

    Study Notes

    Reach and Doorway Requirements

    • Maximum reach height is 48 inches for depths up to 10 inches
    • Maximum reach height is 46 inches for depths between 10 inches and 24 inches
    • Minimum door opening width is 32 inches

    Door Hardware

    • Maximum force required for pushing or pulling interior doors and gates is 5 pounds
    • Maximum force required for pushing or pulling sliding or folding doors is 5 pounds

    Ramps

    • Maximum slope for ramp runs is 1:12 (1 inch rise for every 12 inches of run)
    • Maximum cross slope for ramp runs is 1:48
    • Minimum clear width for ramp runs is 36 inches
    • Maximum length of a ramp run without a landing is 30 feet
    • Maximum rise for any ramp run is 30 inches
    • Ramps must have landings at the top and bottom of each run
    • Landings must comply with section 405.7

    Handrails

    • Handrails must be continuous within the full length of each stair flight and ramp run
    • Inside handrails on switchback or dogleg stairs and ramps must be continuous between flights or runs
    • Handrails on ramps in assembly areas are not required to be continuous in aisles serving seating

    HVAC Systems

    • Heating is the technology of indoor environmental comfort
    • Ventilation is the process of exchanging air between the outdoors and a conditioned space to dilute contaminants and improve air quality
    • Air conditioning is the process of controlling temperature, humidity, and air circulation to provide comfort

    Human Comfort

    • Thermal comfort standards aim to satisfy 80% of occupants
    • ASHRAE 55 is the Standard for Thermal Comfort
    • Thermal Comfort is influenced by temperature, humidity, air quality, acoustics, lighting, physical aspects, and psychosocial situations

    Thermal and Humidity Control

    • Temperature standards for thermal comfort are 75 degrees Fahrenheit with 50% relative humidity
    • Lower temperatures are tolerable with slightly elevated humidity

    Air Distribution

    • Dampers regulate airflow
    • Balancing dampers regulate airflow into a space
    • Fire dampers close ducts to prevent fires from transferring through ductwork
    • Smoke dampers close ductwork to prevent smoke from being distributed throughout a building

    Air Distribution Sizing

    • Factors that impact overall duct sizing include occupant load, room use, building use, exterior envelope, lighting, equipment, and outdoor conditions

    Building Code Ventilation

    • Ventilation systems must be designed to supply the minimum outdoor airflow rate
    • Ventilation rates are based on occupancy classifications, occupancy density, and airflow rates
    • Ventilation systems must supply the required rate of ventilation air continuously during building occupancy
    • Smoking lounges are an exception, and must have ventilation exceeding code requirements

    CFM and ACH

    • Cubic Feet per Minute (CFM) is the amount of air volume moving through ductwork
    • Air Changes Per Hour (ACH) is the number of times the air within a space is changed per hour

    Air Distribution Ductwork

    • Ductwork size is determined by air velocity, pressure, and volume
    • Ductwork clearance is the duct size plus 2 inches for insulation
    • The last branch of ductwork should be 4 feet from the end of the main duct
    • Maximum length of flexible ductwork is 6 feet
    • Maximum height of ductwork is the distance from the bottom of a structure to the bottom of a finished ceiling minus 6 to 12 inches

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    Description

    Test your knowledge on accessibility standards for reach, doorway requirements, ramps, and handrails. This quiz covers the specifications regarding heights, widths, forces, slopes, and other important regulations. Perfect for students and professionals in architecture or design.

    More Like This

    Use Quizgecko on...
    Browser
    Browser