A320 Technical Questions - Air Systems and Components

EquitablePine avatar
EquitablePine
·
·
Download

Start Quiz

Study Flashcards

Questions and Answers

Which part of the aircraft receives conditioned air?

Cockpit, cargo bays and cabin

What happens when the hot air fault light illuminates on the air conditioning panel?

The hot air press.reg.valve opens and the trim air valves close.

Which type of air does the trim air provide to the air conditioning system?

Warm air

In case of zone controller primary and secondary channel failure, what temperatures are maintained by pack one and pack two?

<p>One maintains cold while the other maintains warm temperatures</p> Signup and view all the answers

What happens when the temperature control unit primary channel fails?

<p>The temperature becomes uncontrollable</p> Signup and view all the answers

In the avionics ventilation system, how is the temperature of the cooling air controlled?

<p>Adding avionics bay air</p> Signup and view all the answers

When should the Ram air switch be used to enable Ram air to the mixture unit?

<p>Only when differential pressure is less than 1 psi</p> Signup and view all the answers

What happens in the avionics ventilation system if there is a primary channel failure in the pack controller?

<p>The secondary computer operates as a backup mode and regulation is not optimized</p> Signup and view all the answers

What happens in the avionics ventilation system if there is a secondary channel failure in the pack controller?

<p>No effect (all modes still available)</p> Signup and view all the answers

What occurs in the avionics ventilation system in the event of a hot air pressure reg.valve failed open?

<p>Cabin temperature will be controlled at the upper limit 30 deg C</p> Signup and view all the answers

Study Notes

Air Conditioning System

  • The mixing manifold receives conditioned air.

Fault Indication

  • The hot air fault light on the air conditioning panel illuminates when there is a hot air fault.

Trim Air

  • Trim air provides cool air to the air conditioning system.

Zone Controller Failure

  • In case of primary and secondary channel failure of the zone controller, Pack One maintains a temperature of 10°C (50°F) and Pack Two maintains a temperature of 18°C (64°F).

Temperature Control Unit Failure

  • When the temperature control unit primary channel fails, the secondary channel takes over.

Avionics Ventilation System

  • The temperature of the cooling air is controlled by the pack controller.

Ram Air Switch

  • The Ram air switch should be used to enable Ram air to the mixture unit when it's necessary to compensate for high bleed air temperatures.

Primary Channel Failure

  • In the avionics ventilation system, a primary channel failure in the pack controller leads to a switchover to the secondary channel.

Secondary Channel Failure

  • In the avionics ventilation system, a secondary channel failure in the pack controller leads to a complete loss of cooling.

Hot Air Pressure Reg. Valve Failed Open

  • In the avionics ventilation system, if the hot air pressure regulator valve fails open, it results in loss of cooling.