Podcast
Questions and Answers
What is the total number of possible states that can be represented by the 4-digit binary number (x1x2x3x4)2 in a 4-quadrant dc chopper?
What is the total number of possible states that can be represented by the 4-digit binary number (x1x2x3x4)2 in a 4-quadrant dc chopper?
Which of the following states is not utilized in a 4-quadrant dc chopper?
Which of the following states is not utilized in a 4-quadrant dc chopper?
In the first quadrant operation of a 4-quadrant dc chopper, what is the binary state when S1 is ON?
In the first quadrant operation of a 4-quadrant dc chopper, what is the binary state when S1 is ON?
A four-quadrant chopper operates with a switching frequency of 1kHz. What is the period of the switching signal?
A four-quadrant chopper operates with a switching frequency of 1kHz. What is the period of the switching signal?
Signup and view all the answers
In a 4-quadrant chopper, what is the voltage control range for the third quadrant of operation when the input voltage is 240 V?
In a 4-quadrant chopper, what is the voltage control range for the third quadrant of operation when the input voltage is 240 V?
Signup and view all the answers
What is the magnitude control ratio of the chopper when it operates in the fourth quadrant with an on-time of 0.75 ms and an off-time of 0.25 ms?
What is the magnitude control ratio of the chopper when it operates in the fourth quadrant with an on-time of 0.75 ms and an off-time of 0.25 ms?
Signup and view all the answers
Study Notes
4-Quadrant DC Chopper
- The 4-digit binary number (x1x2x3x4)2 represents the chopper state, with a total of 16 possible states.
- Only states 0, 1, 4, 6, and 9 are utilized, as the remaining states would either short-circuit the supply source or spoil the symmetry of control.
First Quadrant Operation
- ON state: S1 and S4 are ON, represented by state 9 (1001)2.
- OFF state: only S4 is ON, represented by state 1 (0001)2.
Quadrant Operation Modes
- Four modes of operation: first, second, third, and fourth quadrants.
Example Problem
- A four-quadrant chopper operates with a switching frequency of 1kHz and supplies power to a dc motor with an armature EMF of –216 V.
- Input voltage of the chopper is 240 V.
Control Range and Time Calculations
- Voltage control ranges for the third and fourth quadrants of operation depend on the magnitude control ratio.
- ON-time and OFF-time of the modulating switch can be calculated for specific magnitude control ratios in each quadrant.
- Example:
- Third quadrant operation with magnitude control ratio of –0.95.
- Fourth quadrant operation with magnitude control ratio of –0.75.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
Learn about the different operation modes of a 4-quadrant DC chopper, including first quadrant operation and its ON and OFF states. Understand how the chopper state is represented in binary form.