C -10 FINISH WIRING AND TRIM

ConstructiveSnowflakeObsidian avatar
ConstructiveSnowflakeObsidian
·
·
Download

Start Quiz

Study Flashcards

42 Questions

What is the first step when installing rail extensions on the panelboard?

Turn off all power supplying this equipment

What does pigtailing mean when performing work on a home with older wiring?

Connecting a copper wire to the end of an aluminum wire

What is the most practical application for a floor cord cover?

Used on temporary cords when high foot traffic is present

Equipment marking and labels must be able to:

Withstand the environment involved

Which of the following is NOT part of electrical trim work?

Installing panels

Which of the following locations does NOT allow for insulating foam sealants?

Inside of electrical boxes

What tool is used for bending conduit?

EMT bender

Field-applied hazard markings must be:

Permanently affixed to the equipment and cannot be hand-written

Which of the following can be used to protect Type AC cable?

Guard strip

Labels must be provided for which of the following?

All of the above

All of the above

All of the above are dimmable

Which of the following labels is best suited for the innards of a switchboard that carries high voltage to the circuits?

Warning Arc Flash and Shock Hazard Appropriate PPE Required

What is a requirement when installing T-bar Troffer lights in an office that is 440 square feet?

Lights must have their own wire supports to hang independently from the grid structure

What color marking is required for conductors or busbars that carry the higher voltage to ground and these markings are required at connection points that have a grounded conductor present?

Orange

Who is responsible for protecting both in-house and contracted workers from electrical shock and arc flashes?

Employer

What does the “2” mean in USE-2 or RHW-2 wires?

Permitted to be used at a continuous 90ºC operating temperature

Entries into panels and junction boxes need __________ to protect from water penetration.

Wire seals

A service disconnect must have _______ printed and displayed.

The maximum fault current

Which of the following wires can be used in both grounded and ungrounded PV arrays?

PV wire

Who installs conduit sealant?

Contractor

Which of the following allows for great wire management?

All of the above

A three-way dimmer is used when:

A dimming switch is needed at multiple locations

Per the electrical code, if a house has more than one service disconnect then you must:

Place an additional label stating the location of the additional disconnect

When should an electrician install cable terminators or conduit sealing bushings?

All of the above

What is the purpose of a BOS?

Integrates PV into the building’s load

DC photovoltaic source and output circuits require which of the following labeling?

WARNING: PHOTOVOLTAIC POWER SOURCE

An outdoor light fixture should be marked:

Suitable for wet locations

Which of the following locations is a poor choice for the location of a subpanel?

Areas of easily combustible materials

What is the reason that PV wire must undergo a flame test but USE-2 wire does not?

USE-2 wire is typically installed underground where flames do not appear as often

You should not install dimmer switches for:

Ceiling fans

After rough-in wiring and finish wiring have been completed, what does the owner need to do to power their electronics?

Contact utility company

Which of the following situations allow for hand-written labeling?

Markings that are subject to change

What is the final step after installing extension rails on a panelboard?

Complete lockout/tagout procedures by removing locks and warning tags

In PV installations most of the wiring is connected via a:

Junction box

Which of the following considerations are applicable to PV wiring?

All of the above

Which of the following wires is suitable for PV systems over 1,000 volts?

PV wire

Cable trays or similar raceways carrying service entrance conductors must:

Be labeled

Surface-mounted conduit should be sealed:

At all entry and disconnecting points

Which of the following connectors are commonly used in newer solar wiring?

MC4

What kind of marking would you find on a “rated” enclosure?

Type 3

What is the most common location for terminal lugs?

Batteries in PV systems

What are the three main types of outlets?

Convenience, special-purpose, and lighting

TOTAL QUESTIONS: 42 PASSING RATE: 80% PASSING SCORE: 34