PROPER HANDLING OF X-RAY CASSETTES PDF

Document Details

Uploaded by Deleted User

Naga Imaging Department

Aeron Caberte, RRT

Tags

X-ray cassettes radiologic technology image plates medical imaging

Summary

This document provides a guide on proper handling of X-ray cassettes for radiologic technologists. It covers using cassette holders, carrying procedures, feeding cassettes to a digitizer, erasing residual exposure, and monitoring usage. The guide details the importance of proper handling for equipment longevity and cost savings.

Full Transcript

PROPER HANDLING OF X-RAY CASSETTES By Aeron Caberte, RRT Naga-Imaging Department Objective and Scope 1 Objective 2 Scope Aid radiologic Applicable to all technologists in proper Radiologic Technologists handling of x-ray performing x...

PROPER HANDLING OF X-RAY CASSETTES By Aeron Caberte, RRT Naga-Imaging Department Objective and Scope 1 Objective 2 Scope Aid radiologic Applicable to all technologists in proper Radiologic Technologists handling of x-ray performing x-ray cassettes and image procedures and handling plates. cassettes. Equipment and Reagents X-ray Cassettes Image Plate / IP Cassette Holders Digitizer 14x17, 10x12, and 18x24 Essential component for For proper storage and For processing and (mammogram) image capture protection digitizing images Cassette Holder Usage 1 Proper Placement Place cassettes with IP plate serial number facing upward. Avoid upside down or diagonal positioning. 2 Protection Use rubber-coated holders to prevent damage. Don't place cassettes in slanting positions. 3 After Digitizing Remove cassette from digitizer promptly. Place back in holder based on order. Handling X-ray Cassettes Removal Vertical Carry Use two hands to pull Position cassette with IP cassette from holder, serial number facing upward preventing slips. to avoid IP falling. Horizontal Carry Opening Position IP serial number Gently press both latches sideward and forward when simultaneously downward to carrying horizontally. avoid breakage. Feeding Cassettes to Digitizer Preparation Remove staples, paper clips, and tape from job orders to prevent jamming. Orientation Hold cassette with IP plate serial number facing up. Follow arrow marks on digitizer. Insertion Feed cassette slowly and gently using both hands. Avoid applying pressure. Rotation Alternate cassette use to evenly distribute usage and prolong lifespan. Erasing Residual Exposure Identify Need Process After high-factor procedures, Feed cassette to digitizer. use PRIMARY ERASURE to Wait for blue light indicating prevent shadowing in new completion. images. Completion Remove cassette and return to holder in proper order. Monitoring Cassette & IP Usage Weekly Recording System Navigation Data Retrieval Record image plate exposure Access MENU, select User, enter Use Narrow down Searching to find usage in IP maintenance logbook credentials, and navigate to specific Barcode Numbers for weekly. Calculate Use Frequency. tracking. Cassette and IP Maintenance Logbook Date Cassette Size Cassette Serial No Image Plate Serial Total of Usage Remarks No Radtech Signed by Conclusion 1 Importance 2 Benefits Proper care extends Savings from proper equipment life and handling can lead to reduces unnecessary better employee benefits. costs. 3 Acknowledgment Thank you for adhering to these guidelines for x-ray cassette handling. Thank You We appreciate your time and attention throughout this presentation on proper handling of x-ray cassettes. Your commitment to best practices will ensure the longevity of this critical equipment.

Use Quizgecko on...
Browser
Browser