Digital Image Correlation (DIC) Quick Setup Guide PDF

Summary

This document is a quick setup guide for digital image correlation (DIC) illumination systems, DSM 47100 and DSM 47120. It covers list changes, components, and assembly instructions, making it a valuable resource for technical professionals.

Full Transcript

Digital Image Correlation (DIC) Quick Setup Guide (QSG) DSM 47100: XR-LED Illumination System DSM 47120: XG-LED Illumination System QuickSetupGuide (QSG): DSM 47100 / DSM 47120 List Change › As of May 2023, the design of DSM 47100 & DSM 47120 has changed (cited as V2). − V2 incorporate lenses...

Digital Image Correlation (DIC) Quick Setup Guide (QSG) DSM 47100: XR-LED Illumination System DSM 47120: XG-LED Illumination System QuickSetupGuide (QSG): DSM 47100 / DSM 47120 List Change › As of May 2023, the design of DSM 47100 & DSM 47120 has changed (cited as V2). − V2 incorporate lenses that can be inserted into the slit on the upper side of the illumination system − V2 incorporates a different power connection − V2 incorporates a different polfilter mounting design › > Polfilter must be T9 Star Screw Driver 1x Polfilter bracket seperately purchased. 2x Screws (Short) T9 Star Screw Driver 1x XR/XG-Lighting Unit 2x Screws (Long) 1x Articulated mounting arm - Illumination angle is 5x Exchangeable asymmetric and Optics described as an angle in - 60° x 15° X° x Y°. - 40° x 40° - The optics can be - 60° x 60° mounted in 0° or 90° - 25° x 25° (with text legible from - 30° x 15° 5x Exchangeable Optics front – as pictured) DDS-DIC-QSG-XRXGILLUM-EN-V2 QuickSetupGuide (QSG): DSM 47100 / DSM 47120 Assembly – with Polfilter (Optional Optics) (V2) DDS-DIC-QSG-XRXGILLUM-EN-V2 QuickSetupGuide (QSG): DSM 47100 / DSM 47120 Components – with Polfilter (V1) NOTE >> Polfilter must be Tx5 Hexagon Screw Driver 1x Optic bracket 1x Polfilter bracket seperately purchased. 2x Hex Screws 1.5mm (Small) 1x XR/XG-Lighting Unit 2x M3 washers 1x Articulated mounting arm M3 Hexagon Nut Driver 2x M3 nuts 2x Spacing Cylinders - Illumination angle is 5x Exchangeable asymmetric and Optics described as an angle in - 60° x 15° X° x Y°. - 40° x 40° M3 Hexagon Screw Driver M3 Hexagon Screw Driver - The optics can be - 60° x 60° 2x M3 Hex Screws (Short) 2x M3 Hex Screws (Long) mounted in 0° or 90° - 25° x 25° 5x Exchangeable Optics (with text legible from - 30° x 15° front – as pictured) DDS-DIC-QSG-XRXGILLUM-EN-V2 QuickSetupGuide (QSG): DSM 47100 / DSM 47120 Assembly – with Polfilter (Optional Optics) (V1) 2. Fasten the 2x Hex Screws 1.5mm (Small) NOTE >> Polfilter must be into the holes indicated on the XR/XG-Lighting Unit seperately purchased. using a Tx5 Hexagon Screw Driver 3. Place the polfilter into the Polfiler bracket and close both sides so that the (Optional) 1. Place one of holes align. the exchangeable optics in the optic bracket. 4. Fasten the Polfiler bracket together using the 2x M3 Hex Screws (Short) on one side and the 2x M3 washers with 2x M3 5. Fasten the Polfiler bracket to the XR/XG- nuts on the other side using a M3 Hexagon Lighting Unit using the 2x M3 Hex Screws Screw Driver and M3 Hexagon Nut (Long) with the 2x Spacing Cylinders Driver using a M3 Hexagon Screw Driver DDS-DIC-QSG-XRXGILLUM-EN-V2

Use Quizgecko on...
Browser
Browser